38 PKC SERIES PACKAGED STEPPER DRIVES USER GUIDE
The 4 links allow the adjustment of standby current reduction,
resolution, the selection of a permanent or selectable energise
function and motor current. The range of options available is shown
in Table 3-1.
Link No.
Option
Link Position
Value
LK1
Standby
A
80% of full load
current
B*
50% of full load
reduction
C
Permanent (50%) standby
LK2
Resolution
D
4,000 steps/rev
E
2,000 steps/rev
F
1,000 steps/rev
G*
400 steps/rev
LK3
Energise
H*
Permanently energised
I
Energise externally controllable
CD60M
CD80M
LK4
Motor
J
6A
7.8A
current
K
5.5A
7A
L
4.4A
5.6A
M*
3.8A
4.9A
*Factory settings
Note: LK2 can occupy positions D, E, F or G - there is an unused position between E and F.
Table 3-1. Link Setting Options
Standby
Current Reduction
The standby current reduction links allow you to reduce the motor
current by a percentage of the programmed current when the motor
is stationary. Permanent standby reduces the motor current by 50%
of its programmed value and may be used in combination with motor
current link settings to achieve half the value of the load currents
given in Table 3-1, although no standby current reduction is possible
when used in this manner.
Resolution
The CD60M and CD80M drives offer ministepping as standard,
enabling a maximum resolution of 4,000 steps/rev. Ministepping
operation results in both higher resolution positioning and smooth
low speed rotation.