8
PKC SERIES PACKAGED STEPPER DRIVES USER GUIDE
A disconnect device must be provided which isolates all mains
supply current-carrying conductors. If the mains supply is
permanently connected, a switch or circuit breaker must be included
in the wiring. It must be placed close to the equipment (less than 1
metre) and marked as the disconnecting device for the equipment.
Motor
Connections
Connect the motor leads to TB3 using the connection data on the
following pages. Connect one phase of the motor to terminals 1A
and 1B, and the other phase to terminals 2A and 2B. To reverse the
direction of rotation relative to the direction control input, interchange
the connections to 1A and 1B (see Figure 2-3).
Do not use as drive current setting which exceeds the motor rating.
NOTE: If the PKC was sold with a QM or RM motor (sold in the
USA) refer to the "Digiplan Motor User Guide" supplied with the
motor, or call Digiplan USA. This motor user guide contains
complete wiring and current information for these motors.
TB3
MOTOR
LED1
LED4
RV1
RV2
16
1
30
15
TB2
TB1
1A
1B
2B
2A
MOTOR
PHASES
ZERO PHASE
FAULT
24V ON
HT ON
SLOW
FAST
Figure 2-3. Signal and Motor Connections
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com