![Digiplan PKC Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/digiplan/pkc-series/pkc-series_user-manual_2497761031.webp)
24 PKC SERIES PACKAGED STEPPER DRIVES USER GUIDE
When a limit condition is detected the interlock circuit disconnects all
inputs so that the motor decelerates to a halt. To re-start the motor it
is necessary to change the Direction Request, when the input
conditions will be restored allowing the motor to move off in the
opposite direction. Grounding the positive limit input inhibits motion
when the Direction Request is at "0"; the negative limit input inhibits
motion when the Direction Request is at "1".
+ LIMIT
- LIMIT
DIRECTION
REQUEST
FAST
SPEED
INPUT
INTERLOCK
CIRCUIT
DIRECTION
CONTROL
LATCH
GENERATOR
CURRENT
DECELERATION
GENERATOR
CURRENT
SLOW
CONVERTER
CURRENT
VOLTAGE TO
OSCILLATOR
CONTROLLED
CURRENT
GENERATOR
CURRENT
HOME
CIRCUIT
REFERENCE
FAST
MOTOR
DIRECTION
SLOW
SPEED
INPUT
MOTOR
CLOCK
OUT
HOME
SPEED
INPUT
FAST
MODIFY
COMPARATOR
ACCELERATION
RATE
C
R
Figure 2-8. Ramped Clock Block Schematic