submenu ALTI and press
, you can change between the altimeters by pressing
or
, the value starts to flash and
you can change the height value by pressing
or
to memorize the
value. To reset all three altimeters to the default value of 1013.2 mB, go to the
ALTI parameter without entering it, and press
until you hear a triple beep.
The presence of three altimeters gives you many possibilities. The most used is to
have one setup in the traditional manner, and one set to zero at the landing
ground.
This is a revolutionary system designed by Digifly based on the use of a
sophisticated digital electronic circuit. This gives a very sensitive vario (adjustable
through the n.4 svar parameter) and is immune to interference. All the variometric
indications are subject to this filter. To change this parameter from 1 to 10, goto
the svar parameter, n,4, and press
the value starts to flash. Change the value
and press
to memorize.
Shows the integrated vario values on the screen. Or rather, a slowed down version
of the instantaneous reading. This is adjustable as it can be delayed or immediate.
If you set it to a low value, it’s value is close to the instantaneous reading. Normally
this is the most common setting. It can also be used for example to see if the rate of
lift or sink is improving or getting worse, if the integrator vario reading over a
percentage of seconds is higher than the actual reading, that means that we were
doing better before. You can use it to find the core of a thermal. You set up the
integration interval changing parameter
(in seconds). To change this
parameter , goto the inte parameter, n.5, and press
the value starts to flash.
Change the value from 0 to 60 seconds using
or
and press
to memorize
the value.
en when you see the “net” symbol appear. Press
to switch
between net vario and integrator vario.
Undicates the instantaneous values of the vario with a modulated tone. The
volume is adjustable over three by levels using a long pressure on the
button. As
we explained earlier, you can set the sound level for lift, (param. N.1
), and for
sink, ( param. n.2
). There is a new function which allows you to amplify the
frquency modluation based on the wind conditions and you personal preference.
By changing parameter n.3
, you can choose between 0=classic mode,
1=weak conditions, 2=medium conditions or 3=strong conditions. The
procedure used to change this parameter is described in the paragraph “Improve
3.3
Variometers
3.3.3
Vario
3.3.4 N
3.3.5 Acoustic Vario
3.3.1 Intellivario
3.3.2 Analogue Vario
Shows instantaneous vario readings. These are shown on the analogue display on
the left of the screen by an arrow that indicates lift or sink. You can also see these
values expressed by
hen the arrow moves upwards,
values indicate lift, and vice versa .
Integrator
n.5 INTE
v-up
v-dw
SOUN
. Choose the desired altimeter and press
. Press
numbers in dm/s (0,1m/s). W
et Vario (only speed sensor)
This indicates the vertical velocity of the rising and sinking air masses. To use this
function, you have to have set up the polar of your glider. It’s combined with the
variometer and the anemometer. This is shown on the second numeric indicator
on the top of the scre
Pag.12
INTEG
NETTO
Содержание VI100
Страница 1: ...user manual Vl100 graviter rev 1 09 ...