6.20
SNM15
V.25 bis
Digicom SpA
Example
The modem has to call this number: 0331-263122; sequence will
be the following:
7E FF 13B CRN0331<263122 FCS 7E
Note
: for convenience, the content of message field is displayed
in text and not in hexadecimal form as the remaining sequence
(except the not specified FCS field).
SYNCHRONOUS V.25BIS COMMANDS
COMMAND FORMAT
DESCRIPTION
CRN
CRNXX....XX
REQUEST FOR CALL WITH
TELEPHONE NUMBER
SUPPLIED BY DTE. It is sent from
the DTE to start up the procedure.
The command is always
accompanied by the number to be
dialed.
CRS
CRSXX
REQUEST FOR CALL WITH A
TELEPHONE NUMBER
STORED IN THE DCE. It is the
equivalent of the previous request
with the difference that the number
is already present in the DCE
memory. The command is always
accompanied by two figures to
identify the memory area in which
the number is located.