AT commands
Command mode options
XBee/XBee-PRO® S2C ZigBee® RF Module
251
Parameter range
0 - 0xFFFF [read-only]
Default
Set in firmware
AI (Association Indication)
Read information regarding last node join request.
Status
code
Meaning
0x00
Successfully formed or joined a network. (Coordinators form a network, routers and end
devices join a network).
0x21
Scan found no PANs.
0x22
Scan found no valid PANs based on current SC and ID settings.
0x23
Valid Coordinator or Routers found, but they are not allowing joining (NJ expired).
0x24
No joinable beacons were found.
0x25
Unexpected state, node should not be attempting to join at this time.
0x27
Node Joining attempt failed (typically due to incompatible security settings).
0x2A
Coordinator Start attempt failed.
0x2B
Checking for an existing coordinator.
0x2C
Attempt to leave the network failed.
0xAB
Attempted to join a device that did not respond.
0xAD
Secure join error - network security key not received.
0xAF
Secure join error - joining device does not have the right preconfigured link key.
0xFF
Initialization time; no association status has been determined yet.
Applications should read
AI
until it returns 0x00, indicating a successful startup (coordinator) or join
(routers and end devices).
Parameter range
0 - 0xFF [read-only]
Default
N/A
Command mode options
The following commands are Command mode option commands.
Содержание XBee
Страница 1: ...XBee XBee PRO S2C ZigBee RF Module User Guide ...
Страница 259: ...AT commands Execution commands XBee XBee PRO S2C ZigBee RF Module 259 Parameter range N A Default N A ...
Страница 289: ...Regulatory information ANATEL Brazil XBee XBee PRO S2C ZigBee RF Module 289 ...
Страница 290: ...Regulatory information ANATEL Brazil XBee XBee PRO S2C ZigBee RF Module 290 ...
Страница 303: ...Load ZigBee firmware on 802 15 4 devices Background 304 Load ZB firmware 305 XBee XBee PRO S2C ZigBee RF Module 303 ...