AT commands
I/O settings commands
XBee/XBee-PRO® S2C ZigBee® RF Module
248
PD (Pull Up/Down Direction)
The resistor pull direction bit field (1 = pull-up, 0 = pull-down) for corresponding I/O lines that are set
by the
PR
command.
If the bit is set, the device uses an internal pull-up resistor. If it is clear, the device uses an internal
pull-down resistor. See the
PR
command for the bit order.
Parameter range
0x0 - 0x7FFF
Default
0x1FBF
RP (RSSI PWM Timer)
The PWM timer expiration in 0.1 seconds.
RP
sets the duration of pulse width modulation (PWM) signal
output on the RSSI pin. The signal duty cycle updates with each received packet and shuts off when
the timer expires.
When
RP
=
0xFF
, the output is always on.
Parameter range
0 - 0xFF (x 100 ms)
Default
0x28 (four seconds)
DC (Device Controls)
Bit settings to enable or disable certain behaviors.
Bit Description
0
Joiner Global Link Key. Indicates whether a joiner node uses a global link key or a unique
link key.
1
Network Leave Request Not Allowed. Indicates if a router node discards or accepts
network leave commands.
2
Reserved
3
Reserved
4
Verbose Joining Mode. See
Extended Modem Status frame - 0x98
for a full description.
Parameter range
0-0xFFFF
Default
0x00
Содержание XBee
Страница 1: ...XBee XBee PRO S2C ZigBee RF Module User Guide ...
Страница 259: ...AT commands Execution commands XBee XBee PRO S2C ZigBee RF Module 259 Parameter range N A Default N A ...
Страница 289: ...Regulatory information ANATEL Brazil XBee XBee PRO S2C ZigBee RF Module 289 ...
Страница 290: ...Regulatory information ANATEL Brazil XBee XBee PRO S2C ZigBee RF Module 290 ...
Страница 303: ...Load ZigBee firmware on 802 15 4 devices Background 304 Load ZB firmware 305 XBee XBee PRO S2C ZigBee RF Module 303 ...