Network commissioning and diagnostics
Device discovery
XBee/XBee-PRO® S2C ZigBee® RF Module
110
Transparent operating mode configuration (AP = 0)
To send data to the loopback cluster ID on the data endpoint of a remote device:
1. Set the
CI
command to
0x12
.
2. Set the
SE
and
DE
commands to
0xE8
(default value).
3. Set the
DH
and
DL
commands to the address of the remote (
0
for the coordinator, or the 64-bit
address of the remote).
After exiting Command mode, the device transmits any serial characters it received to the remote
device, which returns those characters to the sending device.
API operating mode configuration (AP = 1 or AP = 2)
Send an
Explicit Addressing Command frame - 0x11
using
0x12
as the cluster ID and
0xE8
as both the
source and destination endpoint.
The remote device echoes back the data packets it receives to the sending device.
RSSI indicators
It is possible to measure the received signal strength on a device using the
DB
command.
DB
returns
the RSSI value (measured in -dBm) of the last received packet. However, this number can be
misleading in ZigBee networks. The
DB
value only indicates the received signal strength of the last
hop. If a transmission spans multiple hops, the
DB
value provides no indication of the overall
transmission path, or the quality of the worst link; it only indicates the quality of the last link.
Determine the
DB
value in hardware using the RSSI/PWM device pin (TH pin 6/SMT pin 7). If you enable
the RSSI PWM functionality (
P0
command), when the device receives data, it sets the RSSI PWM to a
value based on the RSSI of the received packet (this value only indicates the quality of the last hop).
You could connect this pin to an LED to indicate if the link is stable or not.
Device discovery
Network discovery
Use the network discovery command to discover all devices that have joined a network. Issuing the
ND
command sends a broadcast network discovery command throughout the network. All devices
that receive the command send a response that includes:
n
Device addressing information
n
Node identifier string (see
)
n
Other relevant information
You can use this command for generating a list of all module addresses in a network.
ZDO discovery
The ZigBee Device Profile includes provisions to discover devices in a network that are supported on
all ZigBee devices (including non-Digi products). These include the LQI Request (cluster ID 0x0031) and
the Network Update Request (cluster ID 0x0038). You can use the LQI Request to read the devices in
the neighbor table of a remote device, and the Network Update Request for a remote device to
complete an active scan to discover all nearby ZigBee devices. You can send both of these ZDO
commands using the XBee Explicit API transmit frame (0x11). For more information, see
. Refer to the ZigBee specification for formatting details of these two ZDO frames.
Содержание XBee
Страница 1: ...XBee XBee PRO S2C ZigBee RF Module User Guide ...
Страница 259: ...AT commands Execution commands XBee XBee PRO S2C ZigBee RF Module 259 Parameter range N A Default N A ...
Страница 289: ...Regulatory information ANATEL Brazil XBee XBee PRO S2C ZigBee RF Module 289 ...
Страница 290: ...Regulatory information ANATEL Brazil XBee XBee PRO S2C ZigBee RF Module 290 ...
Страница 303: ...Load ZigBee firmware on 802 15 4 devices Background 304 Load ZB firmware 305 XBee XBee PRO S2C ZigBee RF Module 303 ...