API Operation
Frame descriptions
XBee/XBee-PRO® S2C ZigBee® RF Module
167
Frame data
fields
Offset Description
Source Endpoint 15
Source Endpoint for the transmission.
Destination
Endpoint
16
Destination Endpoint for the transmission.
Cluster ID
17
18
Cluster ID used in the transmission.
Profile ID
19-20
Profile ID used in the transmission.
Broadcast
Radius
21
Sets the maximum number of hops a broadcast transmission can
traverse. If set to
0
, the device sets the transmission radius to the
network maximum hops value.
Transmission
Options
22
Bitfield of supported transmission options. Supported values include the
following:
0x01 - Disable retries 0x04- Indirect Addressing
0x08- Multicast Addressing
0x20 - Enable APS encryption (if
EE
=
1
)
0x40 - Use the extended transmission timeout for this destination
Enabling APS encryption decreases the maximum number of RF payload
bytes by 4 (below the value reported by
NP
).
Setting the extended timeout bit causes the stack to set the extended
transmission timeout for the destination address. See
All unused and unsupported bits must be set to
0
.
Data Payload
23-n
Up to
NP
bytes per packet. Sent to the destination device.
Example
The following example sends a data transmission to a device with:
n
64-bit address: 0x00
n
Source endpoint: 0xA0
n
Destination endpoint: 0xA1
n
Cluster ID: 0x1554
n
Profile ID: 0xC105
n
Payload: TxData
Frame data fields
Offset
Example
Start delimiter
0
0x7E
Length
MSB 1
0x00
LSB 2
0x1A
Frame type
3
0x11
Содержание XBee
Страница 1: ...XBee XBee PRO S2C ZigBee RF Module User Guide ...
Страница 259: ...AT commands Execution commands XBee XBee PRO S2C ZigBee RF Module 259 Parameter range N A Default N A ...
Страница 289: ...Regulatory information ANATEL Brazil XBee XBee PRO S2C ZigBee RF Module 289 ...
Страница 290: ...Regulatory information ANATEL Brazil XBee XBee PRO S2C ZigBee RF Module 290 ...
Страница 303: ...Load ZigBee firmware on 802 15 4 devices Background 304 Load ZB firmware 305 XBee XBee PRO S2C ZigBee RF Module 303 ...