AT commands
Serial interfacing commands
XBee/XBee-PRO® S2C ZigBee® RF Module
236
Parameter
Description
0x3
19200 b/s
0x4
38400 b/s
0x5
57600 b/s
0x6
115200 b/s (non-standard baud rates)
0x8
230400 b/s
0x9
460800 b/s
0xA
921600 b/s
Default
0x03 (9600 b/s)
NB (Parity)
Set or read the serial parity settings for UART communications.
Parameter range
Parameter
Description
0x00
No parity
0x01
Even parity
0x02
Odd parity
0x03
Mark parity
Default
0x00
SB (Stop Bits)
Sets or reads the number of stop bits for UART communications.
Parameter range
0x00 - 0x01
Parameter
Configuration
0x00
One stop bit
0x01
Two stop bits
Default
0x00