AT commands
Digi TransPort User Guide
134
S15 Data Forwarding Timer
Units: 10ms
Default: 0
Range: 0-255
S15
is used to set the data forwarding timer for the ASY port in multiples of 10ms. The default
data forwarding time is 20ms and in normal use this there should be no need to change this.
However, setting
S15
to
1
enables a special mode of operation in which data is forwarded as fast
as possible for the data rate for which the port is configured (at 115000bps, this will typically be 2-
3ms).
Note that the default value of
0
is equivalent to setting the register to
2
in order to maintain
compatibility with older systems.
S16 RS422/485 serial port settings
The RS485 option is only available on specific hardware versions.
Units: N/A
Default: 0
Range: 0,2,3, where
0
=RS232,
2
=RS485 full duplex,
3
=RS485 half duplex
Following example shows how to setup and save
ASY 0
in 485 half-duplex mode
AT\port=0
ATS16=3
AT&w
AT\port
The at\port=0 is needed to ensure that subsequent AT commands are directed to the right port
(ASY0). The port settings can be saved permanently using AT&W.
Issue the command
ats16?
and check that the value of this S register is 3. To set it back to RS232
then set
ATS16
to zero and save it with the
&w
command.
S23 Parity
Units: N/A
Default: 0
Range: 0-2,5,6
The value stored in
S23
determines whether the parity used for the ASY port is set to
None
(
0
),
Odd
(
1
),
Even
(
2
),
8Data
Odd
(
5
) or
8Data
Even
(
6
).
Содержание TransPort
Страница 1: ...User Guide Digi TransPort ...
Страница 95: ...Regulatory and safety statements Digi TransPort User Guide 95 TransPort WR41Declaration of Conformity ...
Страница 96: ...Regulatory and safety statements Digi TransPort User Guide 96 ...
Страница 97: ...Regulatory and safety statements Digi TransPort User Guide 97 TransPort WR44 Declaration of Conformity ...
Страница 773: ...Manage files Digi TransPort User Guide 773 For example ...