Specification List
SM-100 V2.00
26 December, 2006
2
nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 12 of 32
SPEC
NO.
SPECIFICATION DESCRIPTION
SM-100
175
30 lb to 15 kg Conversion
W
0 Disable
1 Enable
For UK only.
176
Discount Time on Daily Basis
X
0 No
1 Yes
177
Weight Check Function
W
0 No
1 Yes
178
Unit Price Override per PLU
X
0 No
1 Yes
179
Black Bar Sensing Label
X
0 Normal
1 Black
Bar
Sensing
180
Scroll Message Group
0 Disable
1 Enable
181
Continuos Label
X
0 Disable
1 Enable
182
Character Size for Barcode Data
X
0 Large
1 Small
183
PLU Clear after 10 seconds Time-out
W
0 No
1 Yes
184
Duplicate Unit and Total Price on Label
W
0 No
1 Print
Effective when SPEC158
= 1.
185
Weigh PLU Can Use for Non-weigh PLU and Vice Versa Function Key Enable
0 Disable
1 Enable
186
Print $ and Weight Unit on Label
X
0 No
1 Print
187
Clear Total Data by Server
0
Both Server and Client
1
Server
188
Tare Decimal Point Left Shift for SM-25 FIS3D
W
0 No
1 Yes
189
PLU Auto Delete
0 No
Delete
2 30
Days
1 15
Days
3 90
Days
190
Swap Weight and Unit Price on Receipt
W
0 No
1 Yes
191
Default Item Code Equals to PLU Number
X
0 No
1 Yes
192
Nutrition Template
W
0 Standard
3 Standard
Condensed
For U1 and CA only.
1 Simplified
4 Tabulated
2
Simplified Condensed
5
Tabulated Extra Condensed
193
Nutrition Adjustment Feed
X
Enter value from range 0 to 255
For U1 and CA only.
194
Server IP Address
X
Enter a value between 1 to 254
For Client scale only.
All manuals and user guides at all-guides.com