Specification List
SM-100 V2.00
26 December, 2006
2
nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 27 of 32
SPEC
NO.
SPECIFICATION DESCRIPTION
SM-100
616
Selection of Resolution
X
0 1/3000
2 1/7500
1 1/6000
617
New A/D
W
0 No
1 Yes
618
Weight Single Interval or Multi-Interval
X
0 Single
Interval
1 Multi-Interval
619
PLU Weight Item Commodity Name Display
W
0 Full
Display
2 No
Display
For EB and EP type.
1 Half
Display
620
Tare Accumulation
X
0 Allow
1 Inhibit
Effective when SPEC632
= 0.
621
Tare Subtraction
X
0 Allow
1 Inhibit
Effective when SPEC632
= 0.
622
Manual Clear of Tare
X
0 Allow
1 Inhibit
623
Weight Reset Operation during Tare
X
0 Allow
1 Inhibit
624
Zero Tracking during Tare
X
0 Allow
1 Inhibit
625
Accumulation when Tare
X
0 Allow
1 Inhibit
626
Digit Tare
X
0 Allow
1 Inhibit
627
Decimal Point Figure
X
0 Period
1 Comma
628
Price Rounding Method for Decimal Digits on Weighed Item
X
0 Rounding
2 Cut
Up
1 Truncating
629
Additional Price Rounding Method for Item Price
X
0
No Addition Rounding
4
Rounding for 1
st
Digit
1
¼ Rounding (25 step)
5
Truncate 1
st
Digit
2
Special Rounding (5 step)
6
Cut Up 1
st
Digit
3
5 Floor Rounding (0~4: 0, 5~9: 5)
630
Selection of Auto Clear of Unit Price
X
0 Inhibit
1 Allow
631
Selection of Maximum Capacity
W
0 Capacity
+1d
1 Capacity
+9d
632
Selection of Tare Value Exchange
W
0 Allow
1 Inhibit
Related to SPEC620 and
621.
633
Auto Clear of Tare
X
0 Inhibit
1 Allow
All manuals and user guides at all-guides.com