SM100 ERROR MESSAGE
9. SM100 ERROR MESSAGE
ERROR MESSAGE
The machine beeps and following error messages appear on display, if incorrect
operation is performed.
No.
Error Message
Causes
1
PAPER END
Label sensor sense no label. No more labels. Replace
label roll
2
FEED PAPER FIRST
Label miss feed, press FEED key to align label.
3
PEEL LABEL
Peel sensor activated, remove label away from sensor.
4
CHANGE PAPER
Change paper mode between label and receipt.
6
NON PRINT
No manual printing.
7
UNIT PRICE OVERFLOW
Please check unit price.
9
NON LABEL
No free format is programs. Set a free format or use
standard format.
12
MEMO NOT INITIALIZED
Memory problem. Please clear the memory.
14
HEAD IS NOT CLOSED
Thermal head no closed. Please close thermal head.
16
FILE MEMORY FULL
Not enough memory. Expand memory or delete
unnecessary data.
18
PLEASE REMOVE WEIGHT
Fixed price item, please remove weigh.
19
PLU NOT EXIST
No such PLU data or number exists.
20
TOTAL PRICE IS 0
No total price for item. Unit price, weight or quantity is
0.
24
WEIGHT OF
Weight over maximum capacity when print.
26
TOTAL PRICE OVERFLOW
Total price over the limit to display or print.
29
PLEASE SET TARE VALUE
When force tare is enable, a tare weight must be entered.
39
PLEASE PRESS PLU KEY
Press PLU(#) key. To save data in some procedure.
44
KEY ALREADY ASSIGNED
Preset key already been assigned with function or PLU.
48
PLU DATA INVALID
U1 only. Quantity setting incorrect when using FOR.
49
QTY OF
Quantity data over the limit.
54
BELOW MIN WEIGHT
Weight is below min weight set when printing.
57
PRICE ACC OF
Accumulated quantity over the limit.
59
PLEASE SEE LABEL QTY
Set print label quantity when the function is use.
61
GRAND TOTAL OF
Grand total price over the limit.
71
PRINT INHIBITED
Cannot print weigh item at Prepack mode.
74
SELF SERVICE MODE
Can only use Self-service procedure only.
95
CAL00 ERROR
Zero point calibration error.
96
CALSP ERROR
Full scale point Calibration error.
97
FORMAT ERROR
No free format is program.
98
NO DATA IN REPORT
There is no data in report when printing report.
99
EXCEED WEIGHT QUOTA
CN only. Please reset weight quota.