DI-600 Operation Manual
1.2.5. Load Cell:
Exiting Voltage
: 12V (DC)
Sensitivity (Selectable)
: 0.4mV/V ~3.5mV/V
Input impedance
: 350 Ohm
Maximum number of L/C : Max. 8 pcs L/C connected in parallel (350 Ohm only)
1.2.6. Housing: New design
1.2.7. Calibration: Software Calibration
1.2.8. Power Source: AC 220V (+10%, -15%) 50/60Hz
Or recharge battery 12V 2.7AH
1.2.9. Rechargeable Specification: 12V 2.7AH
a) Continuous Usage:
z
8 Hours for 1 L/C connected & printer installed but not printing when fully charged.
z
Or 5 hours for 8 L/C connected & printer installed but not printing when fully
charged.
z
10 hours for 1 L/C connected & no printer when fully charged.
z
Or 6 hours for 8 L/C connected & no printer when fully charged.
z
Or 1 hour for continuously printing.
b) Charging specification
z
Normally the charging current will be about 1.2A, but it depends on how much
power remained when charging.
z
Please ensure more than 8 hours for charging.
1.2.10. Operation Condition:
Temperature: 0
-
40
℃
Humidity: < 85 % RH
1.3. Main Functions
z
Base Unit selection : kg or g
z
Unit conversion
: between kg and lb
z
Counting
mode
z
Weight & Quantity data can be output via RS-232 port to PC
1.4. Overall View
1.4.1. Layout & Dimension
Page No. 2