background image

 

 

 

 

 

Содержание W210

Страница 1: ......

Страница 2: ...ry effort has been made to ensure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or actions they...

Страница 3: ...12 Overview 12 Using Manual Weighing 12 Fine Weighing 13 Overview 13 Using Fine Weighing 13 At the end of the weighing session 13 Weight on Weigh Scale Memory 14 Zero Tracking 15 Loadbar and platform...

Страница 4: ......

Страница 5: ...uality equipment that withstands tough agricultural conditions The Gallagher Weigh Scale range of weighing systems is simple tough innovative and reliable All of the Weigh Scales in the Weigh Scale ra...

Страница 6: ...and maintenance can extend its life Listed below are guidelines for keeping the Weigh Scale in good condition Don t submerge the Weigh Scale in any liquid Store the Weigh Scale in a cool dry place Av...

Страница 7: ...cket can be mounted on a flat vertical surface or on a round post To mount the bracket on a flat vertical surface for example a square post or board use the outer holes To mount the bracket on a round...

Страница 8: ...o the concrete This will prevent the platform from moving during the weighing session 4 Connect the loadbar cables to the Weigh Scale Note If you are using non Gallagher loadbars ensure the loadbars a...

Страница 9: ...its own will power the Weigh Scale continuously for a minimum of eight hours Charging the battery The battery in the Weigh Scale can be recharged using either a battery charger or an external 12 volt...

Страница 10: ...g and will be displayed whether the Weigh Scale is turned on or off Battery charge status The amount of charge left in the battery is shown by the battery icon located in the bottom left corner of the...

Страница 11: ...3E2361 Weigh Scale W210 User Manual 7 Low voltage shutdown When the battery charge drops to a critical level the Weigh Scale will shut down At this stage it is necessary to recharge the battery...

Страница 12: ...s completely on the platform and ensure that the underside of the platform is kept clear of stones dung etc Loadbars Bolt the platform to the loadbars Ensure platform is placed on a flat and level sur...

Страница 13: ...weighing mode rotate the mode select switch located on the left side of the Weigh Scale A is the automatic mode M is the manual mode F is the fine mode 6 Press the blue Zero button to zero out any we...

Страница 14: ...low of animals across the platform In Automatic mode the Weigh Scale starts weighing the animal as it steps onto the platform After the Weigh Scale has determined an accurate weight it will lock on to...

Страница 15: ...has locked on the measurement will remain on screen the Weight OK light will glow OK will display on the screen and the Weigh Scale will beep 5 If the weight has locked on and you want to re weigh the...

Страница 16: ...e platform Ensure the animal is entirely supported by the platform no hooves on the ground and that no object is resting on the animal 4 Press the green Weigh button After the Weigh Scale has determin...

Страница 17: ...t switch is set to F 2 Check that the displayed weight is zero If it is not press the blue Zero button This will reset the Weigh Scale to compensate for the weight of any dung or dirt that has accumul...

Страница 18: ...e restored to the display when the Weigh Scale is switched back on For example suppose a wool bale is being packed on the platform and the Weigh Scale is turned off when the bale is half full If the W...

Страница 19: ...ceeds sets the Weigh Scale to zero If the accumulation weighs more than the Weigh Scale s zero tracking range zero tracking will not work and the icon will flash To restore zero press the blue Zero bu...

Страница 20: ...eet mounting holes extend beyond top covers for ease of bolting down Slotted top mounting holes fit all sizes of platforms and crushes 6m 20 long tough loadbar cables fitted with high quality connecto...

Страница 21: ...gged steel loadbars Bottom feet mounting holes extend beyond top covers for ease of bolting down 6 m 20 long tough loadbar cables fitted with high quality connectors Fully waterproof No rubber mounts...

Страница 22: ...turdy design No rubber to delaminate or rot Spiral spring metal reinforced cable High quality moisture proof connectors Gallagher Suspension Load Cell 500 kg Features 500 kg capacity loadcells Replace...

Страница 23: ...ns Metric Imperial Length 232 mm 9 25 Width 212 mm 8 5 Height 90 mm 3 5 Weight 2 kg 4 4 lb General Operating Temperature 20 to 50 C 5 to 120 F Accuracy 1 Environmental Protection Rating IP65 Input Vol...

Страница 24: ...y Loadbars 4500 kg Automatic or Manual modes 0 49 9 kg 200 g increments 500 g increments 50 199 9 kg 500 g increments 500 g increments 200 499 9 kg 1 kg increments 1 kg increments 500 1999 9 kg 2 kg i...

Страница 25: ...ght increments are preset as shown in the table Weight Range Gallagher Suspension Load cells 250 500 kg Automatic or Manual modes 0 49 9 kg 200 g increments 50 499 9 kg 500 g increments 500 1999 9 kg...

Страница 26: ...designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help conserve natu...

Отзывы: