3. Error Message 

3.1. Error Message List & Solution 

DI-600 will display error message if improper operation is performed or system defect. 

No. 

Display 

Contents 

Solution 

01 OF 

Over Flow, weight is over full 
capacity. 

Remove some weight form platform. 

02 LO 

Lower weight, weight value is 
lower then limit of display 
mask weight. 

Add some weight or restart the 
indicator 

03 nOt 

Ad 

A/D error 

Check the A/D board and load cell are 
defective or not. 

04 zErO 

Er 

Zero Point error, not at zero 
point or over start range 

Remove weight on platter or restart 
the scale, otherwise calibrate it again. 

05 Add. 

OF 

Accumulated data over flow 

Clear the total data and operate again. 

06 GrA. 

OF 

Grand Total data over flow 

Clear the grand total. 

If the problems still can not be resolved according to above information, please contact to our 

local dealer or Technical Service Dept. of Shanghai Teraoka via the information which described 

on manual cover. 

 

 

Page No.   

15

All manuals and user guides at all-guides.com

Содержание DI-600

Страница 1: ...SHANGHAI TERAOKA ELECTRONIC Co Ltd Technical Support Dept A 18F East Tower New Hua Lian Building 755 Huai Hai Zhong Road Shanghai China 200020 Tel 86 21 64739918 Fax 86 21 54901934 E mail steservice digi scale com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...Layout and Function 3 1 5 1 Indicators 3 1 5 2 Keyboard 4 1 6 Hardware 4 2 Main Operation 2 1 Power On 5 2 2 Power Off 5 2 3 One Touch Tare 5 2 4 Digital Tare 5 2 5 Tare Clear 6 2 6 Date and Time Setting 6 2 7 Date and Time Recall 6 2 8 Grand Total Data Clear 7 2 8 1 Weight Grand Total Clear 7 2 8 2 Quantity Grand Total Clear 7 2 9 Serial Number Setup 7 2 10 Weight Unit Conversion 8 2 11 Set Point...

Страница 3: ...Check and Print 14 2 15 Printed Ticket Sample 14 3 Error Message 3 1 Error Message List Solution 15 4 Interface Protocol 4 1 Load Cell Connector 16 4 2 RS 232C Port 16 4 2 1 RS 232C Cable Connection 16 4 2 2 RS 232 Protocol 17 4 3 Set Point Connector 20 4 3 1 Set Point Control Cable Specification 20 4 3 2 Set Point Port Specification 20 4 3 3 Set Point Signal ON Timing 20 4 3 4 Set Point Output Co...

Страница 4: ...symbols z 1 battery indicator 1 2 2 Battery Indicator There are 3 levels in battery indicator to display the volume of battery power Fig 6 Fig 5 Fig 4 Fig 3 Fig 2 Fig 1 z Fig 1 means battery not installed and AC power linked only z Fig 2 Fig 4 shows the volume of rechargeable battery in charging or discharging mode z Fig 5 means battery lower Fig 6 is a flash indicator will keep about 2 minutes if...

Страница 5: ...d printer installed but not printing when fully charged z 10 hours for 1 L C connected no printer when fully charged z Or 6 hours for 8 L C connected no printer when fully charged z Or 1 hour for continuously printing b Charging specification z Normally the charging current will be about 1 2A but it depends on how much power remained when charging z Please ensure more than 8 hours for charging 1 2...

Страница 6: ...peration Manual COUNT SET CAL SP1 SP2 SP3 SP4 TO TAL CHECK O K LO W HIGH O kg lb g MEM 0 0 CH T C 1 2 3 4 5 7 8 6 9 S lb M DI 600 Page No 3 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 7: ...set 4 Net Display value is net weight indicator 5 MEM Memory indicator Light on when accumulated 6 Weight range Weight range checking indicator 7 Battery Battery indicator CHECK Light on when in weight checking mode COUNT Counter Mode SET Data set mode CAL Light on when perform the system calibration or spec setting SP1 SP2 SP3 SP4 Set point indicator TOTAL Total Weight accumulation display mode i...

Страница 8: ...in sample quantity setting mode Number Set code number Plus Weight addition Minus Modification total weight Feed The print paper feed Count Entry counting Mode Check Entry check mode and hold switch MEM SEL Set point memory select 1 4 Unit Switch the weight unit Clear Clear data Numeric Number key 1 6 Hardware Microcomputer MCS 51 single microprocessor Winbond w78e58 8 bit Display Drive HT 1620 LC...

Страница 9: ...ators Operation Key Weight 1 2 3 4 5 6 7 8 9 10 11 12 Remarks Weighing mode 0 000 kg Press On Off Key 2 3 One Touch Tare INDICATION FLAG EXPRESS BRIGHT SPARKLING 1 Zero 2 Net 3 STA 4 Count 5 Check 6 MEM 7 OS1 8 OS2 9 OS3 10 OS4 11 Hold 12 ALM Indicators Operation Key Weight 1 2 3 4 5 6 7 8 9 10 11 12 Remarks Weighing mode 0 000 kg Load Tare weight 2 500 kg Ex tare 2 5kg Press Tare Key tare 0 000 k...

Страница 10: ...e Ex 2002 6 9 0 2 0 6 0 9 d Y N d d 020401 d 020609 Press Enter Key Enter t HH NN t 00 00 Input TIME Ex 18 26 1 8 2 6 t 18 26 Press Enter key Enter S PoInt1 Press Tare return to weighing mode Tare 0 000 kg Escape to weighing mode Note If SPEC 07 bit3 1 the clock function will be disabled The date format is yy mm dd the time format is HH MM date format can be set on SPEC18 Bit0 1 2 7 Date Time Reca...

Страница 11: ...Hold 12 ALM 8293225 13964731996 Indicators Operation Key Weight 1 2 3 4 5 6 7 8 9 10 11 12 Remarks Weighing mode 0 000 kg Press Mode key Mode P totAL Press Mode Mode C totAL 12899 Press Clear key Clear 0 Press Enter key Enter d Y N d Press Tare key Tare 0 000 kg Escape to weighting mode Note SPEC 20 Bit 0 should be set as 0 to enable the quantity grand total operation 2 9 Serial number setup INDIC...

Страница 12: ...values OS1 OS2 OS3 and OS4 will be light 2 11 1 Set Point Value Setting INDICATION FLAG EXPRESS BRIGHT SPARKLING 1 Zero 2 Net 3 STA 4 Count 5 Check 6 MEM 7 OS1 8 OS2 9 OS3 10 OS4 11 Hold 12 ALM Indicators Operation Key Weight 1 2 3 4 5 6 7 8 9 10 11 12 Remarks Weighing mode 0 000 kg Press M M M M M M M M S PoInt1 6 000 kg SM1 SP1 data Set SM1 bright Input value Ex 1 000kg 1 0 0 0 1 000 kg SP1 Valu...

Страница 13: ...set point 2 and set point 3 the continuous and fast alarm will alert when weight is reached target weighing range And the range of Set point 1 to 2 and Set point 3 to 4 can be programmed as fine adjustment range Min Max Near Min Target Over Max Zero Set point 1 Set point 2 Set point 3 Set point 4 Capacity Note means slow alarm and means fast alarm Indicators Operation Key Weight 1 2 3 4 5 6 7 8 9 ...

Страница 14: ...range First phase corresponds to the range between set point 1 and 2 Second phase corresponds to the range between set point 2 and 3 Third phase equals to the range between set point 3 and 4 The first and third range has 5 grades of indicators for each and one grade of indicator equals to 20 of weight range between set point 1 2 or 3 4 Ex The system once increment is 5 g Set point data Set point 1...

Страница 15: ...8 OS2 9 OS3 10 OS4 11 Hold 12 ALM Indicators Operation Key Weight 1 2 3 4 5 6 7 8 9 10 11 12 Remarks Weighing mode 0 000 kg Press Count Count 10 PCS Key in quantity 8 5 0 850 PCS Press Enter key Enter 0 000 kg Weighing mode 2 12 3 Sample Quantity Modification and Print Receipt INDICATION FLAG EXPRESS BRIGHT SPARKLING 1 Zero 2 Net 3 STA 4 Count 5 Check 6 MEM 7 OS1 8 OS2 9 OS3 10 OS4 11 Hold 12 ALM ...

Страница 16: ...ighing mode Remove weight 0 000 kg Load weight on 15 500 kg Ex 15 50kg Press key Add 2 41 000 kg Or auto print weight receipt Wait for printing end 15 500 kg Auto return to weighing mode Remove weight 0 000 kg Press key tot 2 41 000 kg Display the total weights stored Press C key Or Press Enter C Enter 0 000 kg Here you can clear or print the total value and grand total operation Wait for printing...

Страница 17: ...ated data Remove all 0 PCS Put one bag 300 PCS Ex 300 pieces Press Add 2 500 PCS With printing the accumulate data Remove all 0 PCS Press key again tot 2 500 PCS Display the total PCS Press C key or Press Enter C Enter 0 PCS Hear you can clear or print the total Wait for printing end 0 PCS Return to weighing mode Note After printed the total value accumulator will be clear to 0 in meantime this to...

Страница 18: ...000kg Auto print grand total weight Press Enter Enter C tOtAL 500 PCS Ex 500PCS Auto print grand total quantity Press Enter Enter D 02 06 1 8 Press Tare key Tare 0 kg Wighting mode Note After printed the grand total value memory will be clear to 0 Sample Receipt of Grand total Printed English 2 15 Printed Ticket Sample 02 06 18 15 28 GRAND TOTAL GT 41 000kg 02 06 18 15 28 GRAND TOTAL GT 500PCS 02 ...

Страница 19: ...rror Check the A D board and load cell are defective or not 04 zErO Er Zero Point error not at zero point or over start range Remove weight on platter or restart the scale otherwise calibrate it again 05 Add OF Accumulated data over flow Clear the total data and operate again 06 GrA OF Grand Total data over flow Clear the grand total If the problems still can not be resolved according to above inf...

Страница 20: ...re Layer 2 RS Blue 9 NC 3 V Red 10 NC 4 V White 11 NC 5 GND Black 12 NC 6 IN Green 13 NC 7 IN Yellow 14 NC 4 2 RS 232C Port The Baud Rate of RS 232C setting is selectable in SPEC 04 and the other parameters are fixed as following 1 Data Length 8 bit 2 Stop Bit 1 bit 3 Parity Bit No 4 2 1 RS 232 Cable Connection DI 600 D Din 8Pin PC D SUB 9 Pins Pin No Signal Name Pin No Signal Name 1 NC 1 NC 2 GND...

Страница 21: ...out weight stability code Total 21 Bytes Header status Net Weight CR Header status Tare Weight CR LF 1 Byte 8 Byte 1byte 1 Byte 8 Byte 1 Byte 1 Byte d With header code and weight stability code Total 23 Bytes Stable status CR Header Code Net Weight CR Header Code Tare Weight CR LF 1 Byte 1 Byte 1 Byte 8 Byte 1byte 1 Byte 8 Byte 1 Byte 1 Byte e g With Header code and weight stability code Net weigh...

Страница 22: ... disabled b Manual Command Data will output after key pressed customer may select to transmit the data right away or hold the command until weight becomes stable through the SPEC setting If weight not stable within certain interval error message ERR C will appear on display Data Flow Stream Output after Weight Stable PC Side DI 600 Side Weight Stable X Seconds Time Out Yes Manual Command Yes No No...

Страница 23: ...ing can define the data It is alter to send the weight data right away or to hold the command unit weight Become stable If weight is not back to stable condition within the certain interval DI 600 transmits NAK 15H to PC Note If ACK signal is sent to DI 600 during digital tare entry or re zero operation NAK signal is sent to PC right away PC Side DS 600 Side Weight Mode X Seconds Stable NAK NAK DA...

Страница 24: ...t Specification 1 Interface Open collector type Passive type 2 Max Rated Input Voltage 24VDC 3 Max Rated Across Current 50 mA 4 External Power VEXT 12VDC 6 15VDC Recommended Max 24VDC 100mA 4 3 3 Set Point Signal ON Timing When the weight display reaches each programmed value the set point signal will be ON The following figure shows an example of the set point signal ON timing Note1 When programm...

Страница 25: ...external devices the set point port can realize the control function according to the weight changing Following is a sample circuitry diagram for out devices control Note This Circuit Diagram is for Referenced only Page No 28 All manuals and user guides at all guides com ...

Отзывы: