DI-600 Operation Manual
Page No.
7
2.8. Grand Total Data Clear
3.8.1. Weight Grand Total Clear
INDICATION FLAG : (
▼
EXPRESS BRIGHT, SPARKLING )
(1) Zero
(2) Net
(3) STA (4) Count (5) Check (6) MEM (7) OS1 (8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation
Key
Weight
1 2 3 4 5 6 7 8 9 10 11 12
Remarks
Weighing mode
0.000
kg
▼
▼
Press [Mode] key
[Mode ]
P. totAL
12.0235
Press [Clear] key
[Clear]
0.000
Press [Enter] key
[Enter]
C. totAL
Press [Tare] key [Tare] 0.000
kg
▼
▼
Escape to
weighting mode
Note: SPEC 20 Bit1 should be set as 0 to enable the grand total operation.
3.8.2. Quantity Grand Total Clear
INDICATION FLAG : (
▼
EXPRESS BRIGHT, SPARKLING)
(1) Zero
(2) Net
(3) STA (4) Count (5) Check (6) MEM (7) OS1 (8) OS2 (9) OS3 (10) OS4
(11) Hold
(12) ALM 8293225 13964731996
Indicators
Operation
Key
Weight
1 2 3 4 5 6 7 8 9 10 11 12
Remarks
Weighing mode
0.000
kg
▼
▼
Press [Mode] key
[Mode ]
P. totAL
Press [Mode]
[Mode]
C. totAL
12899
Press [Clear] key
[Clear]
0
Press [Enter] key
[Enter]
d. Y.N.d
Press [Tare] key
[ Tare ]
0.000
kg
▼
▼
Escape to
weighting mode
Note: SPEC 20 Bit 0 should be set as 0 to enable the quantity grand total operation.
2.9. Serial number setup
INDICATION FLAG : (
▼
EXPRESS BRIGHT, SPARKLING )
(1) Zero
(2) Net
(3) STA (4) Count (5) Check (6) MEM (7) OS1 (8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation
Key
Weight
1 2 3 4 5 6 7 8 9 10 11 12
Remarks
Weighing mode
0.000
kg
▼
▼
Press [ # ]
[ # ]
C.000000
▼
▼
Input CODE
number value
[1][8][5]
[6][2][6]
C.185626
▼
▼
Example: the serial
code is 185626
Press [Enter] key
[ENTER]
0.000
kg
▼
▼
Back to weighting
mode
Note: This serial number can be used for print.
All manuals and user guides at all-guides.com