5.   LEIT RC2ET remote control handset (version SW 

U:1.XX.XX EE 1.XX.XX) to communicate with up to 

99 LEIT-2ET controllers.

6.  LEIT WWS or LEIT WWSE ambient light (solar) powered wireless weather    

  station used to transmit weather 

  data to the LEIT-2ET controller.

 1.3 Tools and Supply Requirements

1.  Standard wire stripper.
2.   Phillips screwdriver (#1) if using the valve clip attachment or the mounting 

column plastic attachment, or Phillips screwdriver (#2) if using the valve box 

mounting dome.

3.   Concrete: approximately one (1) 90 lb (40 kg) bag, if using the mounting 

column installation.

4. 

WATERPROOF WIRE CONNECTORS

 (not included).

 1.4 Quick Installation Setup and Operation Review

In order to establish communication for the first time between a LEIT RC2ET 

handset and LEIT-2ET two station weather based, ambient light (solar) 

powered wireless irrigation controller and the LEIT WWS or LEIT WWSE 

weather station, the following steps must be taken:
1. Charge the LEIT RC2ET handset (see LEIT RC2ET instructions).
2.  Set up the LEIT RC2ET handset (see LEIT RC2ET instructions).
3.   Install the LEIT-2ET controller following the LEIT-2ET installation 

instructions, see Section 2, then set it out in the light for initial charge. 

4. Install the LEIT WWS (with wind sensor) or LEIT WWSE (without wind 

sensor) weather station following the installation instructions inside each 

box and allow the controller and weather station to harness light energy. 

After the weather station has been installed, no wire connection or 

programming is required for the unit’s operation.

10

Содержание LEIT-2ET

Страница 1: ...I N S T R U C T I O N M A N U A L LEIT 2ET Two Station Weather Based Ambient Light Powered Wireless Irrigation Controller...

Страница 2: ...r installation 13 A Valve box mounting dome 13 B Mounting column 15 C Valve mounting 17 2 3 Maximum wire run 18 3 Initial LEIT 2ET connection 18 3 1 Connecting to a LEIT 2ET controller for the first t...

Страница 3: ...he LEIT RC2ET remote control handset Site information entered into the LEIT RC2ET remote control handset is downloaded into the LEIT 2ET controller and with hourly weather data received from the LEIT...

Страница 4: ...nergy Longer brighter days will enable the system to operate over extended parts of the day C Technical Assistance Should you encounter any problem s with this product or if you do not understand its...

Страница 5: ...are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy If not installed and used...

Страница 6: ...scheduled irrigation program by adjusting the valve time duration in percents to compensate for evapotranspiration ET The LEIT 2ET can monitor and receive signals from one 1 to five 5 weather stations...

Страница 7: ...e the two 2 valves at the same time if hydraulic limitations are not exceeded Available with 18 45 cm color coded 16 gauge wires for each valve and rain sensor Built from tough rugged material and is...

Страница 8: ...are needed 1 Control unit LEIT 2ET two station weather based ambient light solar powered wireless controller 2 The controller is installed using one 1 of the mounting configurations available a Model...

Страница 9: ...th HUNTER series ASV HPV ICV PGV SRV IBV and ASVF valves d Model 30 923 use with WEATHERMATIC series 12000 21000 8200CR valves e Model 30 924 use with IRRITROL series 100 200B 205 217B 700 2400 2500 2...

Страница 10: ...n order to establish communication for the first time between a LEIT RC2ET handset and LEIT 2ET two station weather based ambient light solar powered wireless irrigation controller and the LEIT WWS or...

Страница 11: ...ft 8 m from the nearest LEIT 2ET controller 2 1 Solenoid and Valve Installation NOTE Maximum operating pressure is up to 150 PSI 10 5 bar Use DIG s 305DC XXX valve or Model S 305DC solenoid and select...

Страница 12: ...o the left a half turn or until the valve opens see C 7 Splice the solenoid hot wires red to the controller incoming station wire V1 red Splice the solenoid white wire to the single incoming white wir...

Страница 13: ...e is used it can damage the adapter or the sleeve causing the valve to stay open 2 2 Controller Installation Option A Valve Box Mounting Dome color green model 30 830 tan model 30 835 or purple model...

Страница 14: ...or each valve and one 1 pair for sensor connection labeled V 1 V 2 and S on the housing where the wires enter the controller Connect the controller s output station wire V1 red to the hot wires red on...

Страница 15: ...at both ends so that the wires do not get cross connected see 2 Insert the pairs of wires through the bottom of the mounting column and push the wires up through the column until at least 6 15 cm of...

Страница 16: ...r wires through the small hole on the side of the mounting bracket see Finally place the wires with nuts inside the bracket body and secure the plastic bracket into the controller using the four 4 sma...

Страница 17: ...ting phase 2 i b c d 2 Connect the incoming station wire V1 red to the hot wires red on the solenoid using conventional dry splice waterproof connectors Connect the controller incoming station common...

Страница 18: ...he user can also change the existing Client ID of the controller controller default Client ID is AAA as long as it is also changed on the handset after exiting the controller program In addition a des...

Страница 19: ...default ID is AAA this is a security feature If the controller CLIENT ID is changed from AAA to other letters the user must update the handset to the same client ID after exiting the controller progr...

Страница 20: ...w and black wires from the controller with one of each black wires from the sensor using waterproof connectors if sensor is connected the sensor will override the program when triggered 20 10 00 10 00...

Страница 21: ...control system is a series of components consisting of the LEIT 2ET two station weather based ambient light solar powered wireless irrigation controller the LEIT RC2ET remote control handset the LEIT...

Страница 22: ...h S 305DC solenoids or 305DC XXX valves 3 The LEIT 2ET controllers function only with compatible sensors HUNTER MINI CLICK or RAIN BIRD RSD 5 2 Troubleshooting Solenoids 1 Verify that the correct sole...

Страница 23: ...opening completely the adapter being used with the S 305DC solenoid may be too tight the adapter sleeve could be damaged or the valve water passage down stream may be plugged and in need of cleaning...

Страница 24: ...hot wire splices at the valves or splice boxes are tight and made with waterproof connectors 3 12 and 14 AWG direct burial single strand solid core irrigation wires are recommended do not use multi st...

Страница 25: ...25 6 RECORD CHART Customer ID Controller ID Handset ID Location Address Keep this information in a safe place for your records...

Страница 26: ...0 10 00 10 00 10 00 10 00 10 00 10 00 10 00 10 00 RADIO UPLINK RADIO UPLINK LANGUAGE SETUP HELP FIND TURN OFF MANUAL RUN PROGRAM ENVIRONMENT SETUP REPORTS EXIT CONTROLLER SET TIME DATE VERSION MAIN ME...

Страница 27: ...DGET 10 00 WIND SENSOR 10 00 EXIT 10 00 10 00 TIME DATE VERSION 10 00 00 AM MONDAY 7 13 2009 SW V XX EE V XX XX RADIO UPLINK MAIN MENU 10 00 CONTROLLER MENU RADIOCOLLEGAM RADIOCOLLEGAM LINGUA IMPOSTA...

Страница 28: ...ity of DIG CORPORATION There are no warranties which extend beyond the description on the face hereof In the case of purchase of the product for use other than for irrigation purposes DIG CORPORATION...

Отзывы: