4. Pull the two (2) pairs of field wires from the valves
through the center hole in the bottom of the mounting
plastic bracket (see ). There are three (3) sets of wires
from the controller, one (1) pair for each valve and one
(1) pair for sensor connection (labeled V-1, V-2 and S on
the housing where the wires enter the controller). First,
trim the controller’s valve wires to about 3-4” (7-10 cm)
from the controller and then connect the controller
output station wire (V1 red and white) to the incoming
wires (#1 red or colored and white) using two (2)
small
WATERPROOF WIRE NUT CONNECTORS
.
If necessary, repeat the same procedure for valve #2
using the wires labeled V2 (see ). Next, bring the two
(2) yellow (or yellow and black) sensor wires through
the small hole on the side of the mounting bracket
(see ). Finally, place the wires with nuts inside the
bracket body and secure the plastic bracket into the
controller using the four (4) small Phillips screws provided
(see - ).
5. Next, apply a thin layer of cement glue (included with the
column) to the top on the outside area of the column and
slide the controller mounting bracket into place on top of
the column (see ).
6. At the valves, connect the incoming station wire (V1 red) to the hot
wires (red) on the solenoid
USINg CONVENTIONAl DRy-SPlICE
WATERPROOF CONNECTORS.
Connect the controller incoming station
common wire (V1 white) to the white wire on the solenoid
USINg
CONVENTIONAl DRy-SPlICE WATERPROOF CONNECTORS
and, if
needed, repeat for the second valve and sensor. Leave slack in the wires on
each side so that repairs can be carried out easily (see ).
16
Column mounting (phase 1)
e
f
g
Column mounting (phase 1)
h
e
f
g
h
i
f
g