2. Insert the controller into the mounting dome (see ).
3. Insert the controller wires into the valve box cover (see ).
4. Use #2 Phillips screwdriver to attach the mounting dome to the valve
box cover with the #10 Phillips head screws that are included with the
mounting dome (see ).
14
1
3
4
2
5
f
5. There are 6 wires (or three sets) from the controller, one (1) pair for each
valve and one (1) pair for sensor connection (labeled V-1, V-2 and S on
the housing where the wires enter the controller). Connect the controller’s
output station wire (V1 red) to the hot wires (red) on the solenoid. Then
connect the controller’s output station common wire (V1 white) to the white
wire on the solenoid
USINg CONVENTIONAl DRy-SPlICE WATERPROOF
CONNECTORS.
Repeat the same steps for station 2. Leave slack in the wires
on each side so repairs can be carried out easily (see ).
NOTE:
V1 may be identified by label or striped wires.
g
S
d
e
f
g