DIETA MI-MX user manual 5/2019 • Page EN-150
Following instruction is for kettles equipped with an option for performing a manual pressure
test for the safety valve.
Risk of electric shock if instructions are not followed.
The safety valve function test must only be performed by
a person trained for the purpose.
1. Dismantle the kettle’s front panel by loosening bolts in the front / lower part of the kettle.
This allows you to see the pressure gauge and the switch for the safety unit valve test
function.
2. From the control panel, turn on heating. Set the temperature to 125 ° C.
3. When the set temperature has been reached, press the safety valve test switch until the
safety valve is opened (about 1.5 bar / 127 ° C)
4. Visually confirm from the kettle rear part that steam flows out of the safety valve exhaust
pipe
5. If the pressure exceeds 1.5 bar, cancel the test function.
SAFETY VALVE PRESSURE TEST