If the instructions below does not solve the fault, please contact the service immediately.
Kettle is “dead”
• Check the service switch (main leg, service)
• Check main fuses
• Check in the kettle electrical cabinet the connection unit fuse, relay board fuse etc.
(service)
Kettle does not heat
• Is heating programmed and program started? Read the manual.
• Is emergency stop pushed down?
• No power, check fuses (service)
• Kettle tilting limit switch (main leg, service)
• Pressure switch calibration or fault (service)
• Faulty contantor or connection unit or solenoid valve in a steam kettle (service)
Kettle heats very slowly
• Set target temperature higher (maybe a calibration is needed - service)
• Jacket is full of water after chilling. Empty: open lever in front of the kettle; wait until all
water has flown out (see picture in the lower right corner of this page). Be careful: there
may be high pressure and steam in the jacket.
• Faulty heating element or contactor (service)
• Fault in the startup module (service)
• Open wire (service)
• Calibration changed (service)
• Lime build-up on heating elements (service)
Wrong temperature values on display
• Calibration does not help? change PT-100 probe (service)
• Probe wire may be cut or shorted (service)
Kettle does not tilt
• Is lid completely open?
• Check lid limit switch (service)
• Check tilting wiring (startup module!) (service)
• Check tilt fuses on relay board (service)
FAULTS
Содержание MI-MX
Страница 1: ...DIETA MI MX KÄYTTÖOHJE BRUKSANVISNING USER MANUAL FI Suomi 4 51 SE Svenska 52 101 EN English 102 150 ...
Страница 9: ...DIETA MI MX käyttöohje 5 2019 Sivu FI 9 ...
Страница 52: ...DIETA MI MX bruksanvisning 5 2019 Sida SE 52 Svenska BRUKSANVISNING ...
Страница 102: ...DIETA MI MX user manual 5 2019 Page EN 102 English USER MANUAL ...
Страница 151: ......
Страница 152: ...Dietatec Oy Teollisuusneuvoksenkatu 4 FI 00880 Helsinki puh 358 0 9 755 190 info dietatec com Dietakettles com ...