Technical Data
B.4
B.4
Effective Power and Heat Output
Table B-5:
Effective Power and Heat Output
System
Effective Power (W)
Heat Output (W)
DN Series™ 470
Idle Speed
Operation
190
168
250
B.5
B.5
Mechanical Environmental Conditions
Table B-6:
Mechanical Environmental Conditions
Class
Notes
Operation
3M2
Building without significant vibra-
tions caused by other objects
Transport (in original packing)
2M2
All types of commerce vehicles
and trailers as well as rail and air
transport
Storage (in original packing)
1M3
Noticeable vibration and bumps
caused, for example, by ma-
chines or passing vehicles
B.6
B.6
Environmental Conditions
Noise emissions should be taken into account when selecting the installation site. Fans in operation or
the noise produced during a transaction could disturb people in the immediate vicinity of the system and
may therefore need to be diminished with soundproofing. These must comply with the environmental
conditions that apply to the specific system and the maintenance spaces.
Table B-7:
Environmental Conditions
Climatic Environmental Condi-
tions
Air Temperature degree C ( de-
gree F)
Relative Air Humidity (%)
Operation
-40C to 50C (-40F to 122F)
5 to 85
(Inside) 0C to 40C (32 F to
104F )
Transport
-25 C to +60 C (-13 to 140 F)
15 to 98
Storage
-10 C to +40 C (14 to 104 F)
5 to 98
Noise Emissions
Characteristic noise value ac-
cording to ISO 9296
45 dB(A) Idle mode
55 dB(A) Operation (typical oper-
ating cycle)
Copyright © 2021, Diebold Nixdorf
01750332558 D