CINEO C1010
Malfunctions
45
_
ccTalk error
code
Description/Cause
Category
Remedy/hints
By whom
fuge
If necessary, clean centrifuge
(cf.
Chap. "Cleaning the centrifuge", p. 30)
Service
0x0A2018
Measurement timeout during
measurement
Info
If necessary, open lid and upper ac-
ceptance unit
(cf. Chap. "Opening and
closing the upper coin acceptance unit",
p. 21)
and remove objects from coin
validator
Attendant possessing the
key for the upper lock
0x0A2019
Measurement timeout during
compensation
Info
If necessary, open lid and upper ac-
ceptance unit
(cf. Chap. "Opening and
closing the upper coin acceptance unit",
p. 21)
and remove objects from coin
validator
Attendant possessing the
key for the upper lock
0x0A201A
At least one sorting sensor
covered
Critical
Open lid and upper acceptance unit
(cf.
Chap. "Opening and closing the upper
coin acceptance unit", p. 21
or payout
unit
(cf. Chap. "Opening and closing
the coin payout unit", p. 21)
and free
coins from sorting spiral/chutes
If necessary, clean sorting spiral
(cf.
Chap. "Cleaning the coin validator &
sorting spiral", p.31)
and chutes
(cf.
Service Manual)
Attendant possessing the
key for the upper/lower
lock
Service
0x0A2020
Operating voltage low
Critical
Make sure that CINEO C1010 is connect-
ed correctly
(cf. Chap. " Putting the
CINEO C1010 into service", p. 28)
Make sure that the coin validator is
installed correctly
(Service Manual)
Service
Service
0x0A2021
Operating voltage high
Critical
Make sure that CINEO C1010 is connect-
ed correctly
(cf. Chap. " Putting the
CINEO C1010 into service", p. 5)
Make sure that the coin validator is
installed correctly
(Service Manual)
Service
Service
0x0A2022
Coin position sensors affected
by external light
Attention
Open lid and upper acceptance unit
(cf.
Chap. "Opening and closing the upper
coin acceptance unit", p. 21)
and free
coins from validator
If necessary, clean coin validator
(cf.
Chap. "Cleaning the coin validator &
sorting spiral", p. 31)
Attendant possessing the
key for the upper lock
Service
0x0A2023
Coin position sensors covered
Attention
Open lid and upper acceptance unit
(cf.
Chap. "Opening and closing the upper
coin acceptance unit", p. 21)
and free
coins
If necessary, clean coin validator
(cf.
Chap. "Cleaning the coin validator &
sorting spiral", p. 31)
Attendant possessing the
key for the upper lock
Service
0x0A2025
Coin validator checksum error
Critical
Update firmware and/or configuration
Service
Содержание CINEO C1010
Страница 1: ...CINEO C1010 Coin Recycling System User Manual September 2018...
Страница 60: ...CINEO C1010 Appendix 54_ Appendix Installation and Service Dimensions...
Страница 61: ...CINEO C1010 Appendix 55_...
Страница 63: ...CINEO C1010 Appendix 57_ Data Connection Diagram...
Страница 69: ..._ Diebold Nixdorf D 33094 Paderborn Order No 01750262008B...