![DIEBOLD NIXDORF CINEO C1010 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/diebold-nixdorf/cineo-c1010/cineo-c1010_user-manual_2495461048.webp)
CINEO C1010
Malfunctions
42
_
ccTalk error
code
Description/Cause
Category
Remedy/hints
By whom
correct position
0x0A65
Coin validator communication
failure. CINEO C1010 control
unit was unable to establish
communication with the coin
validator
Critical
Make sure that the coin validator is
installed and engaged correctly
(cf.
Chap. "Removing and reinstalling coin
validator"
If necessary, replace validator
(cf.
Chap. "Removing and reinstalling coin
validator")
Service
Service
0x0A66
Coin validator replied with
NACK status code after send-
ing validator a command
Info
0x0A67
Coin validator replied with
BUSY status code after sending
validator a command
Info
0x0A68
Coin validator replied with
wrong checksum
Info
0x0A69
Coin validator replied with
unknown command
Info
0x0A6A
Coin validator replied with not
allowed
Info
0x0A6B
Coin validator replied with bad
parameter
Info
0x8ACC
Coin validator is entering boot
loader mode
Info
0x8ACD
Coin validator is exiting boot
loader mode
Info
0x8ACE
Coin validator sent ACK for
command "verify CRC and set
OK"
Info
0x8ACF
Coin validator sent ACK for
command "write data to
buffer"
Info
0x8AD0
Coin validator sent ACK for
command "compare buffer
with flash"
Info
0x8AD1
Coin validator sent ACK for
command "prepare sector"
Info
0x8AD2
Coin validator sent ACK for
command "erase sector"
Info
0x8AD3
Coin validator sent ACK for
command "copy buffer to
Info
Содержание CINEO C1010
Страница 1: ...CINEO C1010 Coin Recycling System User Manual September 2018...
Страница 60: ...CINEO C1010 Appendix 54_ Appendix Installation and Service Dimensions...
Страница 61: ...CINEO C1010 Appendix 55_...
Страница 63: ...CINEO C1010 Appendix 57_ Data Connection Diagram...
Страница 69: ..._ Diebold Nixdorf D 33094 Paderborn Order No 01750262008B...