_______________________________
DOUGH
MIXER
IRIS
_______________________________
12
- the position must be near an electric panel
with a magnetothermic circuit-breaker;
- the voltage rating of the electricity main must
correspond to the value given on the
identification plate (Fig. 2);
- the electricity main must be equipped with a
grounding circuit that complies with the relative
standards;
- the ambient temperature must be between
+10° and +40°C;
- the machine must not be installed in a work
environment where there is an explosive
atmosphere.
3.2.1 POSITIONING
After the machine has been positioned and
bearing in mind the indications given in section
«3.2 Installation», proceed by ensuring that the
machine stands in a firm and stable way.
The mod. IRIS dough mixer has three wheels,
of which the front one is a castor (7 Fig. 1),
allowing it to be easily moved. After having
complied with the instructions given in the
previous section, lock the machine in the
required position and level it by means of its
adjustable feet (6 Fig. 1).
Fig. 6 – Plug
3.2.2 ELECTRICAL CONNECTION
DANGER
The machine must only be connected to the
electricity main by specialized and authorized
persons.
It is advisable to consult the wiring diagram of
the machine before proceeding.
Check the voltage rating of the electricity main in
the room and make sure that it corresponds to
the operating voltage of the machine’s electrical
system.
After having made the correct connection, start
the machine and make sure that the bowl turns in
the direction indicated by the arrow (18 Fig.1). If
this is not the case, invert two of the phases in
the plug (R and S - Fig. 6).
DANGER
If you are doubtful about the machine’s safety
systems, stop the machine and check them.
You may contact your nearest authorized
assistance service, the importer or the
Manufacturer if necessary.
3.3
GENERAL INSPECTION
WARNING
Carefully check to make sure that the machine
is efficient and that safety devices are
perfectly functional before setting the dough
mixer at work. Make sure that there are no
damaged components, that all the parts have
been installed correctly and that they function
perfectly.
Unsafe safety devices or damaged parts must
be repaired or replaced by specialized
personnel or by an Assistance center
authorized
by
the
Manufacturer.
SECTION 4
Instructions for use