background image

A010322  Rev. 2 

Pagina 5 di 16

 

 

INSTALLATION, OPERATING AND MAINTENANCE MANUAL 

FOR REFRIGERATED SHOWCASES 

1.WARNINGS 

Read this manual carefully before commencing installation. 
The manual has been devised to furnish the user with all the information required to operate the equipment safely, from its transportation 
right through to scrapping. 
The manual must be looked after carefully so that it is available for future reference. In the event the equipment is sold, the manual must 
also be handed over to the new user. 
 
In order to use the equipment correctly: 

 

Do not tamper with the safety devices; 

 

Use the equipment only for the purpose for which it was specifically designed; 

 

Keep unauthorized personnel away from the equipment; 

 

Have maintenance performed by qualified personnel only; 

 

Switch off the equipment in the event of a fault or irregular operation; 

 

Only use spare parts supplied by the Manufacturer or by stockists indicated by the Manufacturer. 

 

WARNING:  ONLY  QUALIFIED  ELECTRICIANS  ARE  AUTHORIZED  TO  ACCESS  THE  MAIN  CONTROL  BOARD  AND  ANY  OTHER 
ELECTRICAL PARTS, WHETHER FOR INSTALLATION OR MAINTENANCE PURPOSES. 

  

The Manufacturer declines all responsibility for damage to property or bodily injury as a result of non-compliance with the instructions and 
warnings contained herein. 
If in any doubt, and whenever the need arises, contact the DEALER. 

2. INTRODUCTION 

The equipment conforms to the EEC Directives 2004/108 CEE e 2006/95 CEE. 
In addition, the following standards have also been applied: EN 55014-1/A1, EN 61000-3-2, EN 61000-3-3, EN 60335.1, EN 60335.2.24. 

3. DESCRIPTION OF THE EQUIPMENT 

The REFRIGERATED SHOWCASE is a glass and polycarbonate cabinet structure with an autonomous refrigerating unit located at the 
top of the showcase. The refrigerated showcase has been designed for installation on top of the Self-Service units with neutral shelf or 
with refrigerated shelf/basin as the models available feature an insulated stainless steel base, or no base at all. 

4.TRANSPORTATION AND HANDLING 

If  the  equipment  is  transported  on  a  pallet,  it  must  be  unloaded  using  a  lift  truck  of  other  appropriate  lifting  means  operated by trained 
personnel. The maximum weight is given in Table A. 
Manoeuvring  errors  might  cause  injury  as  a  result  of  crushing.  Any  knocking  of  the  surfaces  of  the  equipment  will  result  in  immediate 
damage. 
During this phase, anyone not directly involved in the operation must no be allowed to hang around. 
The personnel handling the equipment must wear appropriate personal safety gear (e.g. work gloves, safety boots). 

5. OPERATING CONDITIONS AND TECHNICAL FEATURES 

The  REFRIGERATED  SHOWCASES  have

 

been  designed  solely  for  the  preservation  and  display  of  cold  foods  and  drinks  at  the 

temperatures given in Table A, for use in rooms used for group catering. Any other use shall be considered improper. 
The REFRIGERATED SHOWCASES are

 

available in the configurations featured in Table A. 

5.1 Controls 

The control devices are grouped together on the instrument panel illustrated in Fig. 1.  
The electrical components conform to standards. 

5.2 Protection and safety devices 

See alarms under point 7.3. 

6. INSTALLATION 

6.1 Positioning 

Place the equipment in a ventilated room, away from heat sources, so as to assure a sufficient supply of fresh air in the area taken up by 
the  compressor.  The  REFRIGERATED  SHOWCASE  has  been  designed  for  use  in  a  room  with  a  maximum  temperature  of  32°C.  For 
improved performance, leave a clear space of 300 mm between the room’s ceiling and the uppermost part of the showcase. 
If the room temperature is higher, this may also have an effect on the temperature inside and may result in malfunctioning or damage to 
the  equipment..  Once  installation  is  complete,  the  protective  film  can  be  removed.  This  operation  should  be  performed  very  slowly  to 
prevent  the  glue  remaining  attached  to  the  surfaces.  If  this  happens,  use  kerosene  or  petrol  to  remove  it.  When  cleaning  the 
polycarbonate  top-hinged  doors,  on  the  side  where  the  goods  are  removed,  UNDER  NO  CIRCUMSTANCES  SHOULD  YOU  USE 
SOLVENTS,  ABRASIVE  PRODUCTS  OR  OTHER  CHEMICAL  PRODUCTS;  WHERE  NECESSARY,  USE  DENATURED  ALCOHOL 
AND A SOFT CLOTH. 
 
 
 
 
 
 
 

GB

 

Содержание 8046041

Страница 1: ...Mod IN VTAF15 Production code 8046041 03 2017 ...

Страница 2: ...ER VETRINE ESPOSITRICI REFRIGERATE INSTALLATION OPERATING AND MAINTENANCE MANUAL FOR REFRIGERATED SHOWCASES INSTALLATIONS BEDIENUNGS UND WARTUNGSANLEITUNG FÜR GEKÜHLTE AUSSTELLUNGSVITRINEN NOTICE D INSTALLATION UTILISATION ET ENTRETIEN POUR VITRINES D EXPOSITION REFRIGEREES I GB DE FR ...

Страница 3: ...a su pallet deve essere scaricata mediante carrello elevatore o altro macchinario di sollevamento idoneo manovrati da personale addestrato Il peso massimo è indicato in Tabella A Eventuali errori di manovra potrebbero causare infortuni per schiacciamento Qualora le superfici dell apparecchiatura subissero urti esse sarebbero immediatamente rovinate In questa fase deve essere vietata la sosta nelle...

Страница 4: ... menu conferma comandi visualizza allarmi 6 Led rosso acceso compressore acceso 7 Led rosso acceso sbrinamento in corso 8 Led rosso acceso allarme attivo lampeggiante per allarme tacitato USO Nel corso del normale funzionamento lo strumento visualizza la temperatura rilevata dalla sonda posta nell ambiente refrigerato vetrina vasca piano vano Per visualizzare l attuale valore del set point valore ...

Страница 5: ...e In questo ambito possono essere necessarie riparazioni o sostituzioni Le parti difettose devono essere sostituite solo con materiali e componenti identici a quelli originali o indicati dal Fornitore In caso di sostituzione di componenti o modifica sull apparecchiatura eseguita dall utilizzatore senza il consenso scritto del Costruttore o con ricambi non autorizzati la garanzia decade immediatame...

Страница 6: ... at all 4 TRANSPORTATION AND HANDLING If the equipment is transported on a pallet it must be unloaded using a lift truck of other appropriate lifting means operated by trained personnel The maximum weight is given in Table A Manoeuvring errors might cause injury as a result of crushing Any knocking of the surfaces of the equipment will result in immediate damage During this phase anyone not direct...

Страница 7: ...ses menus confirms commands displays alarms 6 Red LED on compressor running 7 Red LED on defrost in progress 8 Red LED on alarm active flashing when alarm silenced USE During normal operation the instrument displays the temperature measured in the refrigerated area showcase basin top compartment To display the current set point selected temperature press and release the key set the message set wil...

Страница 8: ...wer mains In this case repairs or replacements might be required The faulty parts must only be replaced with materials and components identical to the originals or specified by the Manufacturer The replacement of components or the modification of the equipment by the user without written permission from the Manufacturer or the use of non authorized spare parts shall instantly cause the warranty to...

Страница 9: ...sehen sind 13 TRANSPORT UND WEITERBEFÖRDERUNG Wird das Gerät auf Paletten transportiert ist dieses mittels eines Gabelstaplers oder anderen Hebewerken die von dazu befähigtem Personal zu bedienen sind abzuladen Das Höchstgewicht ist in der Tabelle A angegeben Eventuelle Manövrierfehler könnten zu schweren Körperverletzungen Quetschungen führen Die Oberflächen des Gerätes sind ausreichend gegen Stö...

Страница 10: ...Thermostat Zeichenerklärung 1 Display 2 Taste Wert erhöhen aktiviert die manuelle Abtauung 3 Taste Wert senken manuelle Alarmrücksetzung 4 Gedrückt für wenigstens 5 Sekunden lässt die Funktion Stand by an Taste Verlassen 5 Taste Sollwertzugriff öffnet die Menüs bestätigt Befehle zeigt Alarme 6 Rote eingeschaltete Led Heizwiderstand an 7 Rote eingeschaltete Led laufende Abtauung 8 Rote eingeschalte...

Страница 11: ...werden 17 2 Instandsetzung Eventuell auftretende Betriebsstörungen dürfen ausschließlich von qualifizierten Fachkräften behoben werden nach Möglichkeit ist das Gerät zuvor vom Stromnetz zu trennen Es können sich sowohl Reparaturen als auch der Austausch von Komponenten als erforderlich erweisen Alle defekten Komponenten dürfen ausschließlich gegen gleichwertige oder vom Hersteller empfohlene Mater...

Страница 12: ... levage adapté manoeuvré par du personnel entraîné Le poids maximum est indiqué dans le Tableau A D éventuelles erreurs de manoeuvre pourraient causer des accidents par écrasement Au cas où les surfaces de l appareil auraient subi des chocs elles seraient immédiatement abîmées Pendant cette phase le stationnement à proximité doit être interdit à toute personne qui n est pas directement concernée p...

Страница 13: ...tat digital Légende 1 Afficheur 2 Bouton augmenter la valeur actionnement du dégivrage manuel 3 Bouton diminuer la valeur remise à zéro manuelle des alarmes 4 Pousser min 5 sec pour activer la fonction stand by Bouton fonction de sortie 5 Bouton accès à la valeur de réglage accès aux menus validation des commandes affichage des alarmes 6 Voyant rouge allumé compresseur allumé 7 Voyant rouge allumé...

Страница 14: ...e l alcool et avec un chiffon humide Durant le nettoyage ne pas laver l appareil avec des jets d eau 8 2 Entretien extraordinaire L entretien extraordinaire a lieu en cas de panne ou d anomalie de la part de personnel qualifié si possible avec l appareil débranché du réseau d alimentation Dans ce cadre des réparations ou des remplacements peuvent être nécessaires Les parties défectueuses doivent ê...

Страница 15: ... Supply voltage 50 Hz V 230 230 230 230 Total power kW 1 2 1 2 1 2 1 2 Max weight Kg 135 125 155 145 Tabelle A TECHNISCHE MERKMALE GEKÜHLTE AUSSTELLUNGSVITRINEN TECHNISCHE DATEN Modell MIT ISOLIERTER ABSTELLFLÄCHE OHNE ISOLIERTE ABSTELLFLÄCHE MIT ISOLIERTER ABSTELLFLÄCHE OHNE ISOLIERTE ABSTELLFLÄCHE Außenmaße L Länge mm 1180 1180 1480 1480 P Tiefe mm 640 640 640 640 H Höhe mm 1150 1150 1150 1150 T...

Страница 16: ...A010322 Rev 2 Pagina 15 di 16 Fig 2 SCHEMA DI INSTALLAZIONE INSTALLATION DIAGRAM INSTALLATIONSSCHEMA SCHEMA D INSTALLATION ...

Страница 17: ...LATOR KONDENSATOR M3 MOTORVENTILATOR VERDAMPFER Nv NEONLAMPEN VITRINE Mn KLEMMENBRETT NEONLAMPEN E E VENTIL E VENTI X1 KLEMMENBRETT 230 V EINPHASIG 50 Hz Ig MASTER REFRIGERATION SWITCH GREEN F RADIO INTERFERENCE SUPPRESSOR In SHOWCASE LIGHTING LUMINOUS SWITCH Pr SAFETY PRESSURE SWITCH Tt SHOWCASE TELETHERMOSTAT M1 COMPRESSOR M2 CONDENSER MOTOR DRIVEN FAN M3 EVAPORATOR MOTOR FAN Nv SHOWCASE NEON LI...

Отзывы: