32
The upload completes, the device will be in the state it was in before being de-energized, i.e.:
- In the Home screen without any message of supply interruption;
- In cycle execution, with message POWER FAILURE to indicate the lack of power.
3.0
POWER FAILURE
If there is a power interruption when there is no function, upon restoration of the power supply device
reproposing the status to be before the interruption.
If there is a power interruption when a feature is active, for restoring the same device will behave in
the following manner:
- With chilling or a freezing cycle running, the cycle is resumed by taking into consideration the duration of
the lack of voltage;
- With a conservation running, the cycle continues maintaining the same settings.
If the duration of the interruption of the power supply was such as to cause the error clock (code "RTC"),
you will need to set up again the day and the real time.
Press any key while the buzzer is playing for
switch off
.
4
– DISPLAY
4.0
KEYS
Each of the 6 buttons activate different functions depending on the level of navigation or of the current
function.
Keys
Function
-
Allows you to quickly select a cycle of chilling
-
Once you have selected a chilling cycle, allows to pass from temperature cycle time cycle
cycle
- Within a menu or during a setting: acts as "ESC" key and returns the controller to top of
page
-
Attention: with a cycle in progress button is not active, to interrupt the cycle press for 2
seconds the key "START"
-
Allows you to quickly select a freezing cycle
-
Once you have selected a freezing cycle, allows to pass from a freezing temperature cycle,
time cycle.
-
Once you have selected the chilling cycle/freezing to perform, allows to switch from hard
mode to that soft.