8.1.12 Physical Reset
A user can load the conf iguration of the switch to f actory defaults using a port loop-back. This also loads the f actory
def ault IP conf iguration. This option may be required if the switch IP address is not known and /or the switch is not
communicating over the network. The new conf iguration is available immediately. The f ollowing procedure shows
the steps f or resetting the f actory def aults using loop-back:
a. Loopback between Port-1 & Port-2 of the main switch using standard Ethernet cable
b. Power on the board and wait till the Ethernet connection is established
c. Remove the loopback cable
Note: The f actory def ault conf iguration is only loaded and not stored. To permanently store this conf iguration, ref er