Technical data

Indoor unit

Operating voltage: 

230 V ~ 50 Hz

Current consumption:  max. 6 W 
Mains connection: 

 approx. 1.5 m mains cable 
with mains plug (3 Amp 
Fuse fitted)

Output voltage:  

12 V DC (for door release)

Operating current: 

max. 1 A * (for door release)

Tonal sequence: 

 approx. 80 dB (approx. 1 m 
distance)

Operating temperature: + 5°C to + 40°C 
Dimensions:    

 approx. 93 x 72 x 230 mm 
(w x h x d) (with receiver 
and mounting plate)

Housing material: 

plastic (ABS)

Weight: 

    

 approx. 511 g (approx. 670 g 
incl. receiver and mounting 
plate)

* The door release must meet these specifications.

Core cross section in relation to length of 
cable

 

Core cross section    Max. length

 

0.5 mm 

2

   

  100 m

 

0.8 mm 

2

   

  150 m

 

1.5 mm 

2

   

  200 m

Outdoor unit

Operating voltage: 

from indoor unit (7 V DC)

Dimensions:   

 panel approx. 

 

   

    

 116 x 200 x 16 mm (wxhxd) 
flush mount box approx. 
98 x 164 x 40 mm (wxhxd)

Housing material: 

 plastic (ABS), grey; alumini-
um, matt silver

Weight:       

 approx. 236 g (approx. 321 g 
incl. flush mount box)

IP protection type: 

 IP 20; for use in dry area 
only

Safety instructions

The following instructions are for your own safety 
and satisfaction when operating the DP 601 door 
intercom. Please note that non-compliance with 
these safety instructions can lead to a serious risk 
of accident.

Explanation of the symbols and terms used:

   

Danger!

 failure to observe this instruction  

endangers life and health.

   

Caution!

 failure to observe this instruction  

endangers property.

   

Tip!

 following this advice will help you to 

achieve optimal results.

 

Danger!

•   Do not leave small children unsupervised with 

the packaging material. There is a risk of fatal 
accident by suffocation.

•   Do not leave children unsupervised with the 

device. There is a risk of fatal accident and injury.

•   The door intercom must be isolated from the po-

wer supply for installation and connection. 
Otherwise there is a risk of fatal accident by 
electric shock.

•   Do not damage any gas, electricity, water or 

telecommunication lines when fitting the device. 
This poses a risk of fatal accident, injury and 
damage.

•   Never expose the device to fire, heat or to tem-

peratures of over 50° C for any length of time. 
There is a danger to life from explosion.

•   Handle the cable with care. Install it so that it 

cannot get damaged and does not  
create a stumbling hazard. This otherwise poses 
a risk of fatal accident and injury.

•   Never connect any external voltage to the ter-

minal screws 

Y

U

I

O

u

i

. Otherwise 

there is a risk of fatal accident, injury and fire. 

•   Make sure that the plug of the mains cable 

T

 

is pushed completely into the mains socket 
when connecting the device. 

 

Never touch it with damp hands. Otherwise  

 

there is a risk of electric shock and fatal accident.

•   Use the indoor unit 

Q

 in dry areas only. Never 

allow it to come into contact with water. Do not 

Introduction / Safety instructions

Content_Türsprechanlage_GB.indd   7

29.09.2005   17:22:15 Uhr

Содержание DP 601

Страница 1: ...Operation and Safety Notes Page 5 Door Intercom DP 601 T 12 Cover_T rsprechanlage_GB indd 5 8 30 09 2005 9 09 05 Uhr...

Страница 2: ...A D F H I K L C B E G P i Q W E R T Y U I O P q w y r t e ui o p A S Door Release optional Outdoor Unit Indoor Unit ca 5 Cover_T rsprechanlage_GB indd 9 12 30 09 2005 9 09 09 Uhr...

Страница 3: ...tion Function page 9 Preparation and material required page 9 Choosing the installation positions page 9 Connection page 9 Installation page 10 Operation page 11 Troubleshooting page 11 Maintenance an...

Страница 4: ...allation location must be protected or equipped with a suitable co ver e g a permanently installed canopy The door intercom is intended for private use only Any other use or modi cation of the device...

Страница 5: ...bserve this instruction endangers life and health Caution failure to observe this instruction endangers property Tip following this advice will help you to achieve optimal results Danger Do not leave...

Страница 6: ...do not come into contact with water Protect the indoor unit Q and the outdoor unit from strong magnetic or electric elds and heavy mechanical loads or vibrations Only use the device with the supplied...

Страница 7: ...for sealing work after installation of the ush mount box A standard 12 V DC door release and a second twin core cable with coded cores in accor dance with the instructions of the door release manufac...

Страница 8: ...st cable from the indoor unit Q to the outdoor unit to terminal screw 1 u Connect the second core e g white of the rst cable from the indoor unit Q to the out door unit to terminal screw 2 i Figure G...

Страница 9: ...tor holds the bell button r down longer the ring tone occurs a corresponding number of times Remove the receiver W from the indoor unit Q Speak to the visitor into the bottom part mouthpiece of the re...

Страница 10: ...Warranty This device has a warranty of 3 years from the date of purchase The device was manufactured with care and inspected thoroughly before delivery Ple ase keep your receipt as proof of purchase I...

Отзывы: