9
GB/IE
o
Ensure that the sabotage contact
r
(on the rear of the
housing) is pressed and lies flush against the installation
site surface.
Motion detector
Double-sided adhesive strips
o Attach the motion detector using the two double-sided
adhesive strips.
or
the mounting screws and dowels
c
Danger!
Avoid injury when drilling out the mounting
holes
p
on the rear
o
of the motion detector housing!
m
Attention!
Make sure that the motion detector is not dam-
aged in any way during the drilling of the mounting holes!
o
Unlock the front of the housing of the motion detector
using a small flat-headed screwdriver (see Fig. G) and
separate it from the rear of the housing
o
.
o
Drill out the two preformed breakthrough points
p
to
form the mounting holes using a hand drill / electronic
screwdriver to a diameter of 2 mm. The holes may be
side by side or one under the other.
o
Mark the two mounting holes
p
at the selected instal-
lation position.
o
Drill the two holes for the two dowels (22 x mm) and
insert the dowels into the holes.
o
Mount the rear of the housing
o
by screwing the two
mounting screws (22 x 3 mm) into the dowels.
o
Engage the front of the housing with the top edge of
the rear of the housing
o
. Then pivot the front fully
down until the front engages completely with the rear.
Operation
m
Attention!
To avoid the risk of hearing damage: wear
ear protection and ensure that no people or animals
are standing within a radius of 10 m of the device.
“Arming” (activating) the compact alarms system
o
Press key 1 on the keypad
R
twice. You have now
entered the user code (factory setting 11).
o
Then press key E on the keypad
R
once. You have
now confirmed the user code.
Exit delay
The compact alarm system emits a pip sound, the LED
W
(green) illuminates for approx. 30 seconds. For the period of
the exit delay of approx. 30 seconds you may cross the de-
tection range of the motion detector without triggering the
alarm of the compact alarm system.
If motion is detected during the exit delay period then you
will hear a short pip sound and the 30 second exit delay will
restart. After the exit delay has expired the LED
W
(green)
goes out. The system is armed / activated.
“Disarming” (deactivating) the compact alarm system
Entry delay
If the motion detector detects a motion then you will hear a
short pip sound and an entry delay of approx. 8 seconds is
activated.
o
You have to enter the user code within the period of the
entry delay to disarm the device.
o
Press key 1 on the keypad
R
twice. You have entered
the user code (factory setting 11).
o
Then press key E on the keypad
R
once. You have
now confirmed the user code.
The compact alarm system is disarmed / deactivated
and emits a 2-pip sound to confirm it.
If you have not entered the correct user code then the
compact alarm system emits a 4-pip sound.
Alarm
The alarm is triggered by the following circumstances
(assuming the compact alarm system has been armed):
o
The passive infrared motion detector has detected a
motion and the user code has not been correctly entered
within the entry delay period (8 seconds).
Assembly and installation / Operation
KOE358_GB_IE_FI_SE_NO_Content_619 9
24.10.2006 11:16:18 Uhr