ENGLISH
9
SECTION VALID FOR A MAX LENGTH
OF 20m SINGLE-PHASE
Power / HP Power / kW 220/230V mm
2
110/120V mm
2
0.75-1 0.65-0.7 1.5
2.5
1.5 1.1 2.5
4
2 1.5 2.5
4-6
2.5-3 1.8-2.2 4
-
m
WARNING
Avoid electrical shock hazard. Never use this
compressor with a damaged or frayed electrical cord or
extension cord. Inspect all electrical cords regularly. Never
use in near water or in any environment where electric shock
is possible.
SAFETY VALVE
This compressor is equipped with a safety valve that is set to
avoid over-pressurization of the air tanks. This valve is factory
pre-set and will not function unless tank pressure reaches
this pressure.
m
WARNING: DO NOT ATTEMPT TO ADJUST OR
ELIMINATE THIS SAFETY DEVICE. ANY ADJUSTMENTS TO
THIS VALVE COULD CAUSE SERIOUS INJURY.
If this device
requires service or maintenance, see an Authorized
D
e
WALT
Service Center.
Attachments and Accessories:
For any attachment or accessory you will be using with this
compressor, the maximum allowable recommended pressure
should be clearly marked on the product or should be clearly
noted within the operations manual. Exceeding the pressure
rating of these attachments (including, but not limited to:air
tools, air operated accessories, spray guns, air hose, air hose
connections, tires and other inflatables) could cause them to
fly apart or explode and could result in serious injury.
• Never exceed the maximum allowable pressure
recommended by the manufacturer of any attachment or
accessory you use with this compressor.
DUTY CYCLE:
To ensure long life of your
D
e
WALT
air compressor, do
not operate on more than the duty cycle indicated on the
technical data plate. If, for example, this air compressor
pumps air more than 25% of one hour, then the
compressor’s capability is less than the air delivery required
by the application. Always match the air volume requirements
of the attachment or accessory with the air volume delivery of
the compressor.
To avoid overheating of the electric motor, this compressor
is designed for intermittent operation as indicated on the
technical dataplate (for example, S3-25 means 2.5 minutes
ON, 7.5 minutes OFF).
SAVE THESE INSTRUCTIONS AND MAKE THEM
AVAILABLE TO OTHER USERS OF
THIS TOOL!
OPERATION AND MAINTENANCE
NOTE:
The information contained in this Instruction Manual is
designed to assist you in the safe operation and maintenance
of the compressor. Some illustrations in this Instruction
Manual may show details or attachments that differ from
those on your own compressor.
INSTALLATION
Remove the compressor from its packing, makes sure it
is in perfect condition, checking if it was damaged during
transport, and carry out the following operations:
DPC16PS ONLY
m
Caution: Risk of personal injury. Avoid placing hands
between handle and top panel when assembling to
prevent pinching.
1. Place handle (5) into bushings on top panel (7).
2. Depress snap buttons and slide handle through first
bushings until it stops at second bushings.
3. Reach under top panel and depress snap buttons again
and slide through second bushings.
4. Pull handle all the way up until it stops. Turn knobs (15) to
lock handle in place. IMPORTANT: Always pull handle up
and lock in place before using as a dolly.
5. If not using the dolly feature, loosen knobs and push
handle down until it stops.
LUBRICATION AND OIL - DPC16PS ONLY
m
CAUTION:
The compressor was shipped with oil in the
crankcase. Please check carefully if the oil is at the right
level. Do not attempt to operate this air compressor without
first checking the oil level in the crankcase. Serious damage
can result from even limited operation unless filled with oil
and broken in correctly. Closely follow Initial Set-up under
Operation having completed all required steps.
m
Caution
: Multi-viscosity motor oils, like 10W30, should
not be used in an air compressor. They leave carbon deposits
on critical components, thus reducing performance and
compressor life. Use
D
e
WALT
synthetic or SAE 40, non-
detergent air compressor oil.
1. Place unit on a level surface.
2. Remove dipstick (13) and check oil level. Gradually
add
D
e
WALT
synthetic or SAE 40, non-detergent air
compressor oil if required. NOTE: See Specifications for
pump oil capacity.
m
Caution
: Risk of unsafe operation. Overfilling with oil will
cause premature compressor failure. Do not overfill.
3. Reposition dipstick.
NOTE: Some units (DPC6MRC, DPC10RC) are equipped
with an oil-free pump. There is no oil to replace or check.