SYMPTOM
CAUSE
FIX
Tool operates but does not drive
staples fully.
Speed select setting in wrong position.
Select higher power setting.
Depth adjust setting incorrect.
Adjust tool free depth adjust dial.
Tool not firmly applied to workpiece.
Apply adequate force to tool securing it tightly to workpiece. See
instruction manual.
Material and staple length.
If the unit continues to stall (forcing the need to rotate the stall release
lever) choose the appropriate material and staple length that is not too
rigorous of an application.
Damaged or worn driver tip.
Replace driver with kit, or see authorised service centre.
Damaged actuation mechanism.
See authorised service centre.
Tool operates, but no staple
is driven.
Incorrect staples.
Use only the recommended staples. Refer to
Technical Data
.
Debris in nosepiece.
Clean nose area and watch closely for small pieces of broken staples
stuck in the track.
Debris in magazine
Clean magazine.
Damaged or worn driver.
Replace driver with kit, or see authorised service centre.
Worn magazine.
Replace magazine. See authorised service centre.
Damaged pusher spring.
Replace spring. See authorised service centre.
Jammed staple.
Incorrect staples.
Use only the recommended staples. Refer to
Technical Data
.
Magazine not secured after previous jam clear/
inspection.
Make sure to magazine is latched properly.
Damaged or worn driver.
Replace driver with kit, or see authorised service centre.
Material and staple length.
If the unit continues to stall (forcing the need to rotate the stall release
lever) choose the appropriate material and staple length that is not too
rigorous an application.
Debris in nosepiece.
Clean nose area and watch closely for small pieces of broken staples
stuck in the track.
Damaged pusher spring.
Replace springs. See authorised service centre.
Tool is not yet run-in.
New tools can take 100–500 staples for parts to mesh and wear
in together. Drive shorter staples during this period if experiencing
difficulty fully driving staples.
Worn magazine.
Replace magazine. See authorised service centre.
Staple drives too deep.
Power setting too high.
Select lower power setting.
Depth adjust setting incorrect.
Adjust tool free depth adjust dial.
Staple bends.
Staple hit knot in wood.
Move 76 mm and try again.
Содержание DCFS950
Страница 1: ...DCFS950 Final page size A5 148mm x 210mm ...
Страница 3: ...1 Fig A Fig B 14 13 14 13 12 10 6 9 2 5 8 7 1 4 3 11 14 13 23 XXXX XX XX 17 ...
Страница 4: ...2 Fig D Fig F Fig H Fig J Fig C Fig E Fig G Fig I 5 15 16 2 12 3 6 7 ...
Страница 5: ...3 Fig M Fig N Fig O Fig K 8 Fig L 19 18 21 22 20 ...