English
English
9
8
3. Retract the rack by pulling the rack handle
5
away from
the tool.
nOTE:
If using cartridge designed for a mixing nozzle
to be attached before loading into dispenser, screw the
static mix nozzle onto the cartridge before proceeding
to step 3.
4. Insert cartridge.
5. Line up the cartridge and the cartridge nozzle opening
to assure correct positioning.
6. Push rack handle forward, lining up pistons
6
with the
openings on the cartridge.
7. Remove caps and plugs on the dispensing end of
cartridge.
nOTE:
If using cartridge designed to be loaded into
dispenser before mixing nozzle is attached, screw the
static mix nozzle onto the cartridge.
Adjusting/Setting the Material Dosage
and Rate of Flow (Fig. E)
specifications
Max Speed*:
6-1/8” per minute
Minimum Speed*:
¼” per minute
Max Dose*:
28 - 32 seconds
Min Dose*:
2-5 seconds
* Specifications are estimates and can vary depending upon the tool,
temperature and adhesive type.
Dose Control
The dose control dial
3
is used to set the dosage/amount
of adhesive dispensed per trigger pull.
• To set the dosage, rotate the dosing control dial until
the amount of adhesive needed per trigger
1
pull
is discharged. Keep trigger depressed while applying
adhesive. Dose control will stop the tool automatically.
Speed Control
The speed feature allows you to speed up or slow down the
rate of flow of adhesive.
• To set the rate of flow, rotate the speed control dial
2
to the flow that is best suited to the application.
Changing the speed while using the dosing feature will
reduce or increase the amount of adhesive dispensed.
nOTE:
Both the dose control and speed control dials will act
as an "off" switch when adjusted to their minimum setting.
The tool will not function and the racks will not move when
in this state from either dial.
Fig. E
3
2
OPERATION
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories.
An
accidental start-up can cause injury.
Installing and Removing the Battery Pack
(Fig. F)
CAUTION:
Release trigger and wait for tool to stop
before removing battery pack. Removal of battery
pack or cartridges during operation is prohibited. This
could cause damage to tool or personal injury.
nOTE:
For best results, make sure your battery pack is
fully charged.
Fig. F
9
8
To install the battery pack
8
into the tool handle, align the
battery pack with the rails inside the tool’s handle and slide
it into the handle until the battery pack is firmly seated in
the tool and ensure that it does not disengage.
To remove the battery pack from the tool, press the release
button
9
and firmly pull the battery pack out of the tool
handle. Insert it into the charger as described in the charger
section of this manual.
Proper Hand Position (Fig. G)
WARNING:
To reduce the risk of serious personal injury,
ALWAYS
use proper hand position as shown.
WARNING:
To reduce the risk of serious personal
injury,
ALWAYS
hold securely in anticipation of a
sudden reaction.
Proper hand position requires one hand on the handle to
actuate the trigger, and the other under the front end to
support the weight of the tool and cartridge.
Fig. G
Dispensing Material (Fig. A)
NOTICE:
DO NOT dispense epoxy when it is above or
below manufacturers reccomended temperature.
1. With battery in the tool, close the clutch lever
4
to
engage clutch.
2. Adjust speed control dial
2
and/or dosing control
dial
3
to your need. Refer to
Adjusting/Setting the
Material Dosage and Rate of Flow
.
3. Hold trigger to begin dispensing adhesive.
When Finished Dispensing Or When End Of Cartridge
is Reached:
1. Release trigger
1
.
2. Open clutch lever
4
.
3. Retract rack by pulling back on the rack handle
5
.
4. Remove cartridge.
nOTE:
Store or dispose of used cartridge in accordance
with manufacturer’s instructions and any applicable
laws or regulations.
WARNING:
When not in use, rotate speed control
to the off position and remove battery pack. This
prevents tool from starting unintentionally.
MAINTENANCE
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories.
An
accidental start-up can cause injury.
Cleaning
WARNING:
Blow dirt and dust out of all air vents with
clean, dry air at least once a week. To minimize the risk
of eye injury, always wear ANSI Z87.1 approved eye
protection when performing this.
WARNING:
Never use solvents or other harsh
chemicals for cleaning the non-metallic parts of
the tool. These chemicals may weaken the plastic
materials used in these parts. Use a cloth dampened
only with water and mild soap. Never let any liquid
get inside the tool; never immerse any part of the tool
into a liquid.
NOTICE:
Material left in the cartridge/sausage
holder may dry if left unattended. Do not attempt to
dispense material under this condition. Follow the
adhesive manufacturer's recommendations when
using caulk or adhesive material to reduce the risk of
property damage.
To clean the cartridge holder, follow adhesive
manufacturer's recommendations for cleaning material
from nozzle, barrel plunger and plunger rod.
Accessories
WARNING:
Since accessories, other than those
offered by
D
e
WALT
, have not been tested with this
product, use of such accessories with this tool could be
hazardous. To reduce the risk of injury, only
D
e
WALT
recommended accessories should be used with
this product.
Recommended accessories for use with your tool