2 YEARs FREE sERViCE On DEWAlT BATTERY PACKs
DC9071, DC9091, DC9096, DC9182, DC9280, DC9360, DCB120,
DCB127, DCB201, DCB203, DCB203BT, DCB207, DCB361
3 YEARs FREE sERViCE On DEWAlT BATTERY PACKs
DCB200, DCB204, DCB204BT, DCB205, DCB606
nOTE:
Battery warranty voided if the battery pack is
tampered with in any way.
D
e
WALT
is not responsible
for any injury caused by tampering and may prosecute
warranty fraud to the fullest extent permitted by law.
90 DAY MOnEY BACK gUARAnTEE
If you are not completely satisfied with the performance of
your
D
e
WALT
Power Tool, Laser, or Nailer for any reason, you
can return it within 90 days from the date of purchase with
a receipt for a full refund – no questions asked.
lATin AMERiCA:
This warranty does not apply to products
sold in Latin America. For products sold in Latin America,
see country specific warranty information contained in
the packaging, call the local company or see website for
warranty information.
FREE WARning lABEl REPlACEMEnT:
If your warning
labels become illegible or are missing, call 1-800-4-
D
e
WALT
(1-800-433-9258) for a free replacement.
Troubleshooting Guide
sYMPTOM
CAUsE
REMEDY
Motor does not start
Trigger not depressed
Discharged battery
Speed or Dose setting too low
Battery pack not fully inserted.
Cartridge or sausage fully dispensed
(dispenser shuts off automatically)
• Press trigger.
• Use charger to recharge battery.
• Increase speed setting
• Increase dose setting
• Remove and reinstall battery pack.
• Remove and replace cartridge.
Motor stops suddenly while running
Dose completed
Battery pack not fully inserted.
Cartridge fully dispensed (dispenser
shuts off automatically)
• Release trigger, increase “dose”,
press trigger.
• Remove and reinstall battery pack.
• Remove and replace cartridge.
Motor stops gradually or slows down.
Discharged battery
Speed setting too low
• Use charger to recharge battery.
• Increase speed setting
Motor runs, but adhesive is not
being dispensed.
Clutch open
Cartridge tip not removed
Adhesive too cold
Cured adhesive clogging mixing tube
Cartridge failure (blow by)
• Close clutch.
• Remove tip.
• Warm the adhesive.
• Replace mixing nozzle
(mixing tube).
• Remove cartridge. Clean pistons
and teeth. Install new cartridge.
Adhesive is dispensed very slowly
Discharged Battery
Speed setting too low
Adhesive too cold
Cured adhesive clogging mixing tube
Cartridge failure (blow by)
• Use charger to recharge battery.
• Increase speed setting
• Warm the adhesive.
• Replace mixing nozzle
(mixing tube).
• Remove cartridge. Clean pistons
and teeth. Install new cartridge.
Dispensed adhesive is not
uniformly mixed.
Adhesive too cold.
Cured adhesive in mixing nozzle
Cartridge failure (blow by)
• Warm the adhesive.
• Replace mixing nozzle
(mixing tube).
• Remove cartridge. Clean pistons
and teeth. Install new cartridge.
Rack handle is difficult to push or pull.
Clutch closed
Adhesive built up on rack teeth
Racks are bent or dammaged
• Open clutch
• Remove cartridge. Clean pistons
and teeth. Install new cartridge.
• Have tool repaired at an
authorized service center