background image

www.devonmedicalproducts.com

          

•           1100 First Avenue, Suite 202     King of Prussia, PA 19406          •

          

866.446.0092

The pump will go through its initial prefill stage of 

reaching 10 mmHg in all 4 chambers.

Each treatment will end after its set treatment 

time has elapsed. The user can also end the 

treatment at any time during a treatment session 

by pressing the STOP button on the front panel.

*Note: If the user presses STOP the treatment
  will not pick up from where it left off at.

After the treatment, the device will vacuum air 

from the garment for 1 minute so that it will facili-

tate removal of the garment.

 

(Not Pictured)

*Note: If using one of the larger size sleeves all
  the air may not vacuum out within 1 minute. The
  vacuum setting can go through another 1
  minute cycle by pressing STOP. 

Once the sleeve is deflated, press the power 

switch on the backboard to the OFF position and 

then unplug the power cord.

Once the power indicator light is off, it is safe to 

remove the garment. 

(Not Pictured)

The garment should be loose enough now that 

you can unzip the garment and remove.

(Not Pictured)

13

56

57

58

59

60

61

TREATMENT

56

57

59

Содержание CircuFlow 5200

Страница 1: ...CircuFlow 5200 Quick Setup Guide www devonmedicalproducts com 1100 First Avenue Suite 202 King of Prussia PA 19406 866 446 0092 LB014 Rev B DRAFT 20121002...

Страница 2: ...onmedicalproducts com 1100 First Avenue Suite 202 King of Prussia PA 19406 866 446 0092 TABLE OF CONTENTS Setup Therapy Setup Gradient Mode Pressure Mode Lock Unlock Device Treatment 03 04 05 08 11 12...

Страница 3: ...re the box also contains 1 power cord 1 air blocker and a user manual Remove the protective foam covers on each side and the plastic bag Not Pictured Place the device on a at and stable surface near t...

Страница 4: ...ower indicator on the front panel will then illuminate Upon this display User can directly push START to run the device on FACTORY DEFAULT mode If GRADIENT MODE is desired continue to steps 10 29 If P...

Страница 5: ...h the SHUTTLE KNOB to access GRADIENT MODE It will take you through various parameters PRESSURE GRADIENT TREATMENT TIME CYCLE TIME AND SKIP CHAMBER This display shows the rst parameter PRESSURE turn t...

Страница 6: ...to con rm the new gradient Access the third parameter TREATMENT TIME by turning the SHUTTLE KNOB to the right Push the SHUTTLE KNOB to select TREATMENT TIME You can increase the treatment time by tur...

Страница 7: ...you wish to skip by turning the SHUTTLE KNOB to the right or left Select one only Chamber 1 Chamber 2 Chamber 3 Chamber 4 or No skip Note Skipping a chamber does not mean the chamber selected will not...

Страница 8: ...RESSURE TREATMENT TIME CYCLE TIME AND SKIP CHAMBER This display shows the rst parameter PRESSURE SET Push the SHUTTLE KNOB to select PRESSURE SET then push the SHUTTLE KNOB on the individual chamber y...

Страница 9: ...decrease time by turning to the left treatment time can range from 15 180 minutes increments of 15 minutes Push the SHUTTLE KNOB to con rm the new treatment time Access the third parameter CYCLE TIME...

Страница 10: ...3 Chamber 4 or No skip Note Skipping a chamber does not mean the chamber selected to skip will not fill with air but less air Push the SHUTTLE KNOB to con rm the skipped chamber To exit and complete...

Страница 11: ...currently selected After setting device to desired treatment turn the SHUTTLE KNOB to the right to select Lock De vice Then push the SHUTTLE KNOB to access Lock Device A second screen will appear to...

Страница 12: ...nput Password Turn the SHUTTLE KNOB to select the rst char acter of the password press down and select the second character Press down the SHUTTLE KNOB a second time to input the password If the passw...

Страница 13: ...off at After the treatment the device will vacuum air from the garment for 1 minute so that it will facili tate removal of the garment Not Pictured Note If using one of the larger size sleeves all the...

Страница 14: ...www devonmedicalproducts com 1100 First Avenue Suite 202 King of Prussia PA 19406 866 446 0092 NOTES...

Страница 15: ...www devonmedicalproducts com 1100 First Avenue Suite 202 King of Prussia PA 19406 866 446 0092 NOTES...

Страница 16: ......

Отзывы: