External Meter Interface
–
ZHEMI-101
–
Technical manual
Develco Products A/S
Olof Palmes Allé 40
http://develcoproducts.com
DK-8200 Aarhus N
15
1-0:2.8.2
CurrentTier2SummationReceived
0x0103
0x02
0-0:96.14.0 ActiveRegisterTierDelivered
0x0020
0x02
0-0:96.14.0 ActiveRegisterTierReceived
0x0021
0x02
1-0:1.7.0
1-0:2.7.0
InstantaneousDemand
0x0400
0x02
InstantaneousDemand =
(1-0:1.7.0)-(1-0:2.7.0)
0-0:96.1.1
MeterSerialNumber
0x0308
0x02
If OBIS code not present, will
use meter identification string
instead
0-0:1.0.0
Reading SnapShot Time
0x0007
0x02
0-0:96.3.10 Supply Status
0x0014
0x02
Status
0x0200
0x02
Check meter bit will be set if
no telegrams, or only
telegrams with invalid CRC is
received from meter
0-1:96.1.0
MeterSerialNumber
0x0308
0x40
0-1:24.2.1
Reading SnapShot Time
0x0007
0x40
0-1:24.2.1
Current Summation Delivered
0x0000
0x40
0-1:24.2.1
UnitofMeasure
0x0300
0x40
0-1:24.1.0
MeteringDeviceType
0x0306
0x40
0-1:24.4.0
Supply Status
0x0014
0x40
0-2:96.1.0
MeterSerialNumber
0x0308
0x41
0-2:24.2.1
Reading SnapShot Time
0x0007
0x41
0-2:24.2.1
Current Summation Delivered
0x0000
0x41
0-2:24.2.1
UnitofMeasure
0x0300
0x41
0-2:24.1.0
MeteringDeviceType
0x0306
0x41
0-2:24.4.0
Supply Status
0x0014
0x41