4.1.5.2
0x03 Formatting attribute set
The following set of attributes provides the ratios and formatting hints required to transform the received
summations, consumptions or demands/rates into displayable values. If the Multiplier and Divisor attribute values
are non-zero, they are used in conjunction with the SummationFormatting, ConsumptionFormatting, and
DemandFormatting attributes.
Id#
Name
Type
Range
Man/Opt
Note
0x00
UnitofMeasure
8 bit enum
0x00 to 0xFF
M
Set based on unit in “
0-
n:24.2.1
”
0x01
Multiplier
Uint24
0x000000 to
0xFFFFFF
O
Fixed to 1
0x02
Divisor
Uint24
0x000000 to
0xFFFFFF
O
Fixed to 1000
0x03
SummationFormatting 8 bit bitmap
0x00 to 0xFF
M
0x06
MeteringDeviceType
8 bit bitmap
0x00 to 0xFF
M
Set based on “
0-n:24.1.0
”
Supported: Gas, Water and
Electricity
Above attribute description is to be found in section D.3.2
.2.4 “Formatting”
ZigBee Smart Energy Profile
Specification provided by the ZigBee alliance.
4.1.5.3
OBIS code mapped into ZigBee attributes
When the interface mode is configured to “P1 dutch standard –
DSMR 4.0 version” the following OBIS code are
mapped into the following ZigBee attributes:
OBIS Code ZigBee Attribute Name
ZigBee
Attribute Id
ZigBee
Endpoint
Comment
1-0:1.8.0
CurrentSummationDelivered
0x0000
0x02
If OBIS code not present, will
be the sum of 1-0:1.8.1 and 1-
0:1.8.2
1-0:2.8.0
CurrentSummationReceived
0x0001
0x02
If OBIS code not present, will
be the sum of 1-0:2.8.1 and 1-
0:2.8.2
1-0:1.8.1
CurrentTier1SummationDelivered
0x0100
0x02
1-0:2.8.1
CurrentTier1SummationReceived
0x0101
0x02
1-0:1.8.2
CurrentTier2SummationDelivered
0x0102
0x02