4
Clusters
4.1.1
Basic cluster
The Basic cluster has 2 attribute sets defined. In the following sections the attributes of these sets is listed. Refer
to
[Z2]
for ZigBee specification of the basic cluster.
Id#
Name
Type
Range
Man/Opt
Note
0x0
ZCLVersion
Uint8
Type range
M
0x4
ManufacturerName
String
0-32 byte
O
0x5
ModelIdentifier
String
0-32 byte
O
0x7
PowerSource
8 bit enum
Type range
M
4.1.1.1
ManufacturerName
“Develco”
4.1.1.2
ModelIdentifier
“ZHEMI
101
”
4.1.1.3
PowerSource
Battery
4.1.1.4
Manufacture Specific Attribute
Id#
Name
Type
Man/Opt
Relevance and ref.
0x8000
Primary SW Version
OctetString
M
Read only
ZCL header setting
–
Manufactor code for Develco Products is 0x1015
4.1.2
Identify
–
Cluster id 0x0003
The identify cluster serves as a way to make a device identify itself either visually or by sound.
Normally this is done by toggling an LED at some interval.
Refer to
[Z2]
for ZigBee specification of the identify cluster.
The Identify cluster only defines one attribute.
4.1.2.1
Attribute
Id#
Name
Type
Range
Man/Opt
Relevance and ref.
0x0000
IdentifyTime
Uint16
Type
range
M