Panic Button - PBTZB-110
–
Technical manual
Develco Products A/S
Tangen 6
http://develcoproducts.com
DK-8200 Aarhus N
9
0x01
Identify Query
none
M
0x01
The identify cluster has 1 command as client.
Id#
Name
Payload
Man/Opt
Relevance and ref.
0x00
Identify Query Response
Uint16 - Identify Time (seconds)
M
0x00
4.2
IAS Zone Device
–
EP 0x23
4.2.1
IAS Zone - Cluster id 0x0500
The IAS Zone cluster is described in ZigBee Cluster Library Specification.
4.2.1.1
Attribute
Id#
Name
Type
Man/Opt
Relevance and ref.
0x0000
Zone State
8-bit
Enumeration
M
0x0001
Zone Type
16-bit
Enumeration
M
Hard coded to
Personal emergency device
0x0002
Zone Status
Uint16
M
The
following
bits
are
supported:
Bit1: Alarm 2
Bit3: Battery
Bit4: Supervision reports
Bit5: Restore reports
0x0010
IAS CIE Address
Valid 64-bit
IEEE address
M
0x0011
ZoneID
Uint8
M
4.2.1.1.1
Zone State
The device will automatically start to scan the network for an IAS Zone client in a predefine interval. When the
client is found it will automatically attempt to enrol. When it has successfully enrolled the Zone Status command
is send to the IAS Zone client.
The attribute value will change from not enrolled (0x00) to Enrolled (0x01).
4.2.1.1.2
IAS CIE Address
Attribute specifies the address that commands generated by the server shall be sent to.
To un-enrol the device the back end system has to write a new address into this attribute. Any value is valid. If the
back end system writes an IEEE address then it will try to enrol to this devices represented by the IEEE address.