Panic Button - PBTZB-110
–
Technical manual
Develco Products A/S
Tangen 6
http://develcoproducts.com
DK-8200 Aarhus N
18
6
General network behaviour
6.1
Installation
When the device is virgin and powered for the first time it will start looking for a ZigBee PAN Coordinator or router
to join. The device will scan each ZigBee channel starting from 11 to 24. The LED will flash once every second until
it joins a device.
#Scan mode - 1
Scan all 16 ZigBee
channel until join
network or 3
minutes
#factory storage mode - 2
MCU is in sleep mode
(Radio off)
Press button to reactivate
scan mode
Scan mode 1 will only be activated when the user presses the panic button. It the devices doesn’t join a ZigBee
network it will go back to factory storage mode. Press panic button again to reactivate scan mode
If the user invokes EZ-mode it will start scanning the next 3 minutes
In section 5 “MMI” it is explained how to put the device into a join or leave network mode.
Network settings are stored in NV-memory are after a power cycle the device re-join the same network.
If the device has to join a
new PAN coordinator the MMI menu supports a “
Reset To Factory Fresh Settings
” mode.
This will erase all current network information.
6.2
Low battery
The current battery voltage can be read from the power configuration cluster described in section 4.3.1. The
attribute “
BatteryVoltage
”
is measuring the battery voltage, in units of 100mV.
Low batt LED indication
–
RED LED will blink twice every 60 second