Panic Button - PBTZB-110
–
Technical manual
Develco Products A/S
Tangen 6
http://develcoproducts.com
DK-8200 Aarhus N
10
4.2.1.1.3
ZoneID
A unique reference number allocated by the CIE at zone enrolment time.
Used by IAS devices to reference specific zones when communicating with the CIE. The
ZoneID
of each zone stays
fixed until that zone is un-enrolled.
4.2.1.2
Commands
The IAS Zone cluster has 2 commands as server.
Id#
Name
Payload
Man/Opt
Relevance and ref.
0x00
Zone Status Change
Notification
Uint16
–
bit mask
M
0x01
Zone Enroll Request
Bits
16
16
M
Data type
16 bit enum
UINT16
Field
name
Zone
type
Manufacturer
code
Init sequence
–
when the device has join the network it start to scan for an IAS zone client cluster. If a client is
found a Zone enroll request command is send and a Zone Enroll response is expected. If it doesn’t receive a
response it will wait for 15 minutes and try again.
The following bits are supported in Zone status:
Bit1: Alarm 2
Bit3: Battery
Bit4: Supervision reports
Bit5: Restore reports
Bit0, Alarm
Note: How to clear a alarm in the “Zone status”
The sensor requests ZCL Default Response on the Zone Status Change notification, if any new Alarm bit has been
set. Until the IAS CIE has acknowledged the received alarm by sending the mandated Default Response, the
Alarm bits are not cleared
–
even if there is no longer an alarm situation. When the Default Response is received, a
new Zone Status Change notification is sent with the Alarm bits cleared, if the alarm situation has disappeared
since sending the Zone Status message with alarm set.
Bit3:
When the battery is below 2.2 VDC. Battery bit is set high
and “Zone Status” is transmitted to the coordinator.