Panic Button - PBTZB-110
–
Technical manual
Develco Products A/S
Tangen 6
http://develcoproducts.com
DK-8200 Aarhus N
11
4.2.2
Power Configuration - Cluster id 0x0001
The power configuration cluster is described in ZigBee Cluster Library Specification
4.2.2.1
Attribute
Id#
Name
Type
Range
Man/Opt
Relevance and ref.
0x0020 BatteryVoltage
Uint8
0x00 - 0xFF
O
ZCL configure reporting is
supported
Note: The attribute “
BatteryVoltage
” is measuring the battery voltage, in units of 100mV.
4.2.3
Poll Control - Cluster id 0x0020
The poll control cluster is described in ZigBee Cluster Library Specification
This cluster provides a mechanism for the management of an end device’s MAC Data Request rate. For the
purposes of this cluster, the term “poll” always refers to the sending of
a MAC Data Request from the end device
to the end device’s parent.
This cluster can be used for instance by a configuration device to make an end device responsive for a certain
period of time so that the device can be managed by the controller.
4.2.3.1
Attribute
Id#
Name
Type
Range
Man/Opt
Relevance and ref.
0x0000
Check-inInterval
Uint32
0x00 - 0xFF
M
Default value is 1 hour
0x0001
LongPoll Interval
Uint32
M
Default value is disabled
0x0002
ShortPollInterval
Uint16
M
Default value is 3
seconds
0x0003
FastPollTimeout
Uint16
M
Default value is 5 minutes
Start up, auto scan for client poll control cluster on the coordinator. If it is support on the coordinator an auto bind
is created and the smoke sensor will send a check-in command in the
interval specified in attribute “Check
-
inInterval. The coordinator has to reply with a check-in response. The sensor supports the following commands
send from the client (Typically the coordinator).
•
0x00 Check-in Response,
•
0x01 Fast Poll Stop,
•
0x02 Set Long Poll Interval,
•
0x03 Set Short Poll Interval,
If it doesn’t find a poll client it will search again periodically.