background image

 

 

 

 
 

 

 

 

 

 

Panic Button - PBTZB-110 

Technical manual 

Revised 29.07.2021 

 

 

 

Содержание PBTZB-110

Страница 1: ...Panic Button PBTZB 110 Technical manual Revised 29 07 2021 ...

Страница 2: ...n clusters for each end point 8 4 1 1 Basic Cluster id 0x0000 8 4 1 1 1 Attribute 8 4 1 2 Identify Cluster id 0x0003 8 4 1 2 1 Attribute 8 4 1 2 2 Commands 8 4 2 IAS Zone Device EP 0x23 9 4 2 1 IAS Zone Cluster id 0x0500 9 4 2 1 1 Attribute 9 4 2 1 2 Commands 10 Note How to clear a alarm in the Zone status 10 4 2 2 Power Configuration Cluster id 0x0001 11 4 2 2 1 Attribute 11 4 2 3 Poll Control Cl...

Страница 3: ...Time Cluster id 0x000A 14 4 2 5 1 Attribute 14 5 MMI user guide 15 5 1 Accessing and re enabling MMI menu 15 5 2 Push Button Menu 15 5 2 1 EZ mode Initiator 16 5 2 2 EZ mode Target 16 5 2 3 Factory reset 16 5 3 Action on Power On 16 6 General network behaviour 18 6 1 Installation 18 6 2 Low battery 18 7 Specifications 19 8 Contact Information 20 ...

Страница 4: ...co Products assumes no responsibility for any errors which may appear in this manual Furthermore Develco Products reserves the right to alter the hardware software and or specifications detailed herein at any time without notice and Develco Products does not make any commitment to update the information contained herein All the trademarks listed herein are owned by their respective owners RoHS ...

Страница 5: ...ionary notes Develco Products A S reserves the right to make changes to any product to improve reliability without further notice Develco Products A S does not assume any liability arising out of the application or use of any product or circuit described herein neither does it convey any license under patent rights or the rights of third parties ...

Страница 6: ...ing them to easily alert friends and family or healthcare professionals if an emergency occurs Being more vulnerable to all kinds of dangers elderly and disabled can benefit from an easy way to call for help in case of an emergency With the Panic Button they can simply press a button to alert others if they need help The Panic Button can help elderly and disabled gain more independence and securit...

Страница 7: ...x23 Application profile Id 0x0104 Home Automation Application device Id 0x0402 3 3 Develco Utility Application profile Id 0xC0C9 Develco Products private profile Application device Id 0x0001 Manufactor code for Develco Products is 0x1015 Private profile for internal Develco Products use only Reference documents 053474r18ZB_CSG ZigBee Specification pdf 075123r03ZB_AFG ZigBee_Cluster_Library_Specifi...

Страница 8: ... relevant to a Develco device are all in set 0x000 4 1 1 1 Attribute Id Name Type Range Man Opt Relevance and ref 0x0 ZCLVersion Uint8 Type range M 0x4 ManufacturerName String 0 32 byte O 4 1 1 1 1 0x5 ModelIdentifier String 0 32 byte O 4 1 1 1 2 0x6 DateCode String 0 32 byte O 0x7 PowerSource 8 bit enum Type range M 4 1 1 1 1 ManufacturerName Develco Products A S 4 1 1 1 2 ModelIdentifier PBTZB 1...

Страница 9: ...following bits are supported Bit1 Alarm 2 Bit3 Battery Bit4 Supervision reports Bit5 Restore reports 0x0010 IAS CIE Address Valid 64 bit IEEE address M 0x0011 ZoneID Uint8 M 4 2 1 1 1 Zone State The device will automatically start to scan the network for an IAS Zone client in a predefine interval When the client is found it will automatically attempt to enrol When it has successfully enrolled the ...

Страница 10: ...client is found a Zone enroll request command is send and a Zone Enroll response is expected If it doesn t receive a response it will wait for 15 minutes and try again The following bits are supported in Zone status Bit1 Alarm 2 Bit3 Battery Bit4 Supervision reports Bit5 Restore reports Bit0 Alarm Note How to clear a alarm in the Zone status The sensor requests ZCL Default Response on the Zone Sta...

Страница 11: ... parent This cluster can be used for instance by a configuration device to make an end device responsive for a certain period of time so that the device can be managed by the controller 4 2 3 1 Attribute Id Name Type Range Man Opt Relevance and ref 0x0000 Check inInterval Uint32 0x00 0xFF M Default value is 1 hour 0x0001 LongPoll Interval Uint32 M Default value is disabled 0x0002 ShortPollInterval...

Страница 12: ...EEE Address M 0x0001 FileOffset Uint32 Type range O 0x0002 CurrentFileVersion Uint32 Type range O 0x0003 CurrentZigBeeStackVersion Uint16 Type range O 0x0004 DownloadedFileVersion Uint32 Type range O 0x0005 DownloadedZigBeeStackVersion Uint16 Type range M 0x0006 ImageUpgradeStatus 8 bit enum 0x00 to 0xFF O 0x0007 Manufacturer ID Uint16 Type range O 0x0008 Image Type ID Uint16 Type range O 0x0009 M...

Страница 13: ...Panic Button PBTZB 110 Technical manual Develco Products A S Tangen 6 http develcoproducts com DK 8200 Aarhus N info develcoproducts com 13 4 2 4 3 OTA Upgrade Messages Diagram ...

Страница 14: ... hrs 0 mins 0 sec on 1st January 2000 Refer to Z2 for ZigBee specification of the time cluster The device will use this clusters as a client provided that a suitable Time Server is available on the network most likely on the Gateway 4 2 5 1 Attribute Id Name type Range Man Opt Relevance and ref 0x0000 Time UTCTime Uint32 Type range M The module will periodically update its clock by synchronizing t...

Страница 15: ... 2 can be used instead Method 1 Press and hold the button for 10 seconds When the LED flashes green release the button immediately Method 2 Remove the battery wait 10 seconds and re insert it into the device 5 2 Push Button Menu When MMI menu is active the user can push the button and select the different menus described below Pushing the button for longer push hold for a few seconds and release a...

Страница 16: ...2 2 EZ mode Target If the devices is not on the network EZ Mode Network Steering is invoked when the user enter this menu The led blinks twice every 1 sec until the devices has joined the network If the device was already on the network it will broadcast the PermitJoin messages It is the trust center policy that decides if the device is allowed to join the network When the device has joined the ne...

Страница 17: ...8200 Aarhus N info develcoproducts com 17 If a device has joined a network and is powered down it will attempt to rejoin this network upon power up For the first 30 seconds hereafter the device will be available for communication This time can be expanded using the poll control cluster functionality ...

Страница 18: ...ser presses the panic button It the devices doesn t join a ZigBee network it will go back to factory storage mode Press panic button again to reactivate scan mode If the user invokes EZ mode it will start scanning the next 3 minutes In section 5 MMI it is explained how to put the device into a join or leave network mode Network settings are stored in NV memory are after a power cycle the device re...

Страница 19: ...White Optional Orange marking on the button Battery Battery CR2450 Coin Cell Battery life Up to 5 year Radio Sensitivity 100 dBm Output power 10 dBm Environment Water resistant when used in the bathtub and shower Operation temperature 0 to 50 C Function Button Panic alarm Communication Wireless protocol ZigBee Home Automation compliant ZigBee end device Certifications Conforming to CE RoHS and REA...

Страница 20: ...roducts com DK 8200 Aarhus N info develcoproducts com 20 8 Contact Information Technical support Please contact Develco Products for support products develcoproducts com Sales Please contact Develco Products for information on prices availability and lead time info develcoproducts com ...