Customer Documentation DEV 5071
Copyright DEV Systemtechnik GmbH 2007-2017
27
Note:
The representation of the rear side of the device is mirrored in the Status
Tab (i.e. visible as when looking at the rear side of the DEV 5071), this
means, that the AC connector of power supply module 4 is located on
the left side and that the AC connector of power supply module 1 is
located on the right side.
In addition, the voltages of DEV 5071 are shown as unsigned values, i.e.
not stating the polarity of the output voltage; please refer to
chapter 4.2.2.
In the lower part of the window on the left side, the Active Events Window is
located. This window shows appearing and pending errors with the
corresponding error message and a date/time stamp.
The "AC Line 3" error shown in the Active Events Window of the screenshot
was triggered for demonstration purpose, just by pulling a primary power
connector. To obtain more details on the errors detected by the device,
please click on the Error Log button to open the Error Log Window:
5.4.3.1 Error Log Window
The Error Log Window is to be opened with the Error Log button located in
the Status Tab below the Active Events Window.
The Error Log Window displays a table of the errors, which were detected by
the device.
The different errors are listed in the table line-by-line, i.e. each error carries a
Date/Time
stamp (in the format: "
DD.MM.YY hh:mm:ss
", here "
17.12.13 18:13:29
")
informing about the last occurrence of that error. The 2
nd
column is a