DS7400Xi-AT (Ver. 3+) Reference Guide Copyright © 1995-2000 Detection Systems, Inc. Page 7
@ 12 VDC, Alarm.
• DS7481:
Single Phone Line Monitor (1 per system).
The DS7481 provides a means of monitoring a single
phone line for fault conditions. When a fault is detected,
the DS7481 automatically closes its Normally Open
relay contacts to provide a means of signaling the
fault.
• Current Draw = 20 mA, Standby. 20 mA, Alarm.
• DS7488:
Octal Relay Module (2 per system).
The DS7488 provides 8 Form “C” relay outputs for
addition to the system. The outputs are fully
programmable and can be activated by system
events. Each output operates individually of the other
7 outputs for complete flexibility.
• Current Draw = 10 mA + 40 mA for each relay
when energized.
• DS7489:
Solid State Output Module (2 per system).
The DS7489 is a Solid State Octal Driver Module that
provides 8 open collector transistor outputs. The
outputs are fully programmable and can be activated
by system events. Each output operates individually
of the other 7 outputs for complete flexibility. The
DS7489 Module has not been investigated by
Underwriters Laboratories, Inc.
• Current Draw: 10mA.
• Outputs: Provides a current sink (the output
shorts to common (-) when activated). The
maximum current draw for all 8 outputs combined
cannot exceed 750 mA.
• MX280:
Multiplexed Photoelectric Smoke Detector (up to 120
detectors may be used per system. Requires a
DS7430 and occupies one multiplex zone). Detects
smoke and automatically determines the detector’s
sensitivity using the Detection Systems “Chamber
Check” feature. The MX280 Detector has not been
investigated by Underwriters Laboratories, Inc.
• Current Draw: 500 mA Standby, 560 mA Alarm.
• MX280TH:
Multiplexed Photoelectric Smoke Detector with a
135°F (57°C) heat sensor (up to 120 detectors may
be used per system. Requires a DS7430 and occupies
one multiplex zone). Detects smoke and is equipped
with a 135°F (57°C) heat sensor for high temperature
alarms. The Detection Systems “Chamber Check”
feature automatically determines the detector’s
sensitivity. The MX280TH Detector has not been
investigated by Underwriters Laboratories, Inc.
• Current Draw: 500
µ
A Standby, 560
µ
A Alarm.
• MX280THL: Multiplexed Photoelectric Smoke Detector with a
135°F (57°C) heat sensor and a 45°F (7°C) freeze
alarm (up to 60 detectors may be used per system.
Requires a DS7430 and occupies two multiplex
zones). Detects smoke and is equipped with a 135°F
(57°C) heat sensor for high temperature alarms and
a 45°F (7°C) sensor for freeze alarms. Freeze alarms
are reported separately from smoke and high
temperature alarms. The Detection Systems
“Chamber Check” feature automatically determines
the detector’s sensitivity. The MX280THL Detector has
not been investigated by Underwriters Laboratories,
Inc.
• Current Draw: 500
µ
A Standby, 560
µ
A Alarm.
• MX540:
Passive Infrared (PIR) Intrusion Detector with a stan-
(DS7473) dard range of 40 by 50 feet (12 by 15 meters). Requires
a DS7430 and occupies one multiplex zone.
• Current Draw = 800
µ
A Standby and Alarm.
• MX835:
TriTech® Microwave/PIR Intrusion Detector with Pet
Immunity technology and a standard range of 35 x 35
feet (10.7 x 10.7 m). Requires a DS7430 and occupies
one multiplex zone.
• Current Draw= 6 mA standby, 35 mA in “Trouble”
and walk test mode.
• MX775:
Passive Infrared (PIR) Intrusion Detector with a stan-
(DS7470) dard range of 50 x 50 feet (15 x 15m). Requires a
DS7430 and occupies one multiplex zone.
• Current Draw= 200
µ
A standby, 2 mA in
walk test mode.
• MX794:
The MX794 is a Long Range Multiplex PIR Intrusion
(DS7474) Detector with Self-test. The standard ranges are 80 ft.
by 50 ft. (24.0m by 15.0m) and 200 ft. by 10 ft.
(61.0 m by 3.1 m). Requires a DS7430 and occupies
one multiplex zone.
• Current Draw = 800
µ
A Standby and Alarm.
• MX934:
Passive infrared (PIR) intrusion detector with a stan-
(DS7471) dard range of 35 by 35 feet (10.7m by 10.7m). Re-
quires a DS7430 and occupies one multiplex zone.
• Current Draw= 200
µ
A standby, 2 mA in
walk test mode.
• MX938:
360° Ceiling Mount Multiplex PIR Intrusion Detector
(DS7472) with a 60 foot (18.3m) diameter range. Requires a
DS7430 and occupies one multiplex zone.
• Current Draw= 200
µ
A standby, 2.5 mA in
walk test mode.
• MX950:
TriTech® Microwave/PIR Intrusion Detector with
motion (DS7476) monitor and anti-mask features and
with a standard range of 50 x 50 feet (15 x 15m).
Requires a DS7430 and occupies one multiplex zone.
• Current Draw= 6 mA standby, 35 mA in “Trouble”
and walk test mode.
• RF7434-ITI: 16 zone Wireless Receiver. Up to 2 RF7434-ITI re-
(60-731)
ceivers may be used per system. Requires the use
of a DS7430 Multiplex Expansion Module. See ITI
Inguide P/N 466-1426 for installation information.
• Current Draw = 35 mA Standby and Alarm.
• Requires a DS7447 Keypad.
• RF7435-ITI: 120 zone Wireless Receiver. One RF7435-ITI re-
(60-731)
ceiver may be used per system. Requires the use
of a DS7430 Multiplex Expansion Module. See ITI
Inguide P/N 466-1426 for installation information.
• Current Draw = 35 mA Standby and Alarm.
• Requires a DS7447 Keypad.
• ARDIS
SM
Communications Module: This Communications
Module provides a means of communicating alarm
and supervision signals using the ARDIS radio
network. This can be a replacement for, or a
complement to, the standard digital communicator.
• Current draw: 127 mA Standby and Alarm.
Содержание DS7400Xi-AT
Страница 11: ...DS7400Xi AT Ver 3 Reference Guide Copyright 1995 2000 Detection Systems Inc Page 11 5 0 System Worksheet...
Страница 76: ...DS7400Xi AT Ver 3 Reference Guide Copyright 1995 2000 Detection Systems Inc Page 76 Pager Format Continued...
Страница 78: ...DS7400Xi AT Ver 3 Reference Guide Copyright 1995 2000 Detection Systems Inc Page 78 14 1 SIA Formats Continued...
Страница 79: ...DS7400Xi AT Ver 3 Reference Guide Copyright 1995 2000 Detection Systems Inc Page 79 14 2 CID Formats...
Страница 94: ...DS7400Xi AT Ver 3 Reference Guide Copyright 1995 2000 Detection Systems Inc Page 94 Installation Notes...
Страница 95: ...DS7400Xi AT Ver 3 Reference Guide Copyright 1995 2000 Detection Systems Inc Page 95 Installation Notes...
Страница 96: ...DETECTION SYSTEMS INC...