PRO COMPACT & CAD D300 v2.4
Page 27
Appendix A4: Instructions for the Sterilizing Cartridge
With the watermaker OFF:
Ø
Close the seawater inlet valve.
Ø
Open the sterilizing cartridge:
be careful not to lose the O-ring
.
Ø
Remove the top screen.
Ø
Place the foam at the bottom of the filter.
Ø
Pour the sterilizing powder into the cartridge.
Ø
Replace the top screen and close the cartridge.
Ø
Check that the seal is correctly in place.
Ø
Remove the 5 & 25 micron cartridges from the prefilter.
Ø
Replace it with the sterilizing cartridge
Ø
Turn the rinsing valve to the fresh water position for about 20 seconds.
Ø
Please note that this procedure is very quick. The watermaker should not be turned on.
Ø
Duration of sterilization: 6 months maximum (to be repeated beyond that)
➥
Important
: Before the next start-up, rinse the system out using fresh water for 15 minutes.
Remove the ST2 sterilizing cartridge and replace it with a 5-micron cartridge.
WARNING!
The ST2 cartridge can be reused.
Remove the 5- and 25-micron
cartridges from the prefilter
Replace the 5-micron
cartridge with the ST2
sterilizing cartridge