PRO COMPACT & CAD D300 v2.4
Page 10
3) Motor Block
Ø
To ensure optimal production, the assembly of the high-pressure motor block must be
completed in a horizontal position and in an area protected from water sprays.
Ø
Use the 2 stainless steel legs under the 2 motors to fix the motor block. Leave a
few centimetres of wiggle room around it.
Ø
Provide sufficient airflow for the ventilation of the motors.
Ø
The connection of the prefilter outlet to the inlet of the pump on the suction-side
pump should be done using Tricoflex piping Ø 15mm (inside diameter) and 2
stainless steel collars at each connection.
Ø
The connection of the pump's high-pressure head to the membrane inlet (red mark)
should be done using a high-pressure hose that is cut to size (follow closely the
assembly instructions in
Appendix A2
).
Ø
Put a little liquid
Loctite
542 or threadlock on the male and female cones before each
connection.
Ø