5) Membrane Block
Ø
The membrane block should preferably be mounted horizontally (on the base or
side). A vertical position could lead to a yield/output loss over time.
Ø
Fastening is done using self-tapping screws in the stainless-steel brackets .
Ø
It is necessary to sheath the pipe connecting the output of the high pressure pump
to the inlet of the membranes
because of the vibrations, which might lead to
leaks if the pipe is attached or in direct contact with something.
Ø
The installation of the high-pressure nozzles must be carried out according to their
assembly instructions (see
Appendix A2
).
Ø
Put some Loctite or threadlock on the 2 male and female cones before tightening.
Ø
Available as an option: 90° elbow high-pressure nozzle for the inlet and outlet of
the membranes .
6) Control panel
The control panel must be mounted on a vertical panel.
Ensure unrestricted access to the back of the control panel, this will make connections
easier. You should place it in a place where the light indicators are visible.
Example: below or on the sides of cupboards, under the chart or centre table, on the front
panel of a rear berth etc.